The critical sensor: A new type of evanescent wave immunosensor

被引:7
作者
Schipper, EF
Kooyman, RPH
Borreman, A
Greve, J
机构
[1] MESA Research Institute, Department of Applied Physics, University of Twente, 7500 AE Enschede
关键词
immunosensor; planar waveguides; deflection; critical angle; evanescent wave sensor;
D O I
10.1016/0956-5663(96)88416-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new planar waveguide immunosensor has been developed in which adsorption at a surface, changing the refractive index contrast, is measured. In this ''critical'' sensor the change in the effective refractive index contrast is transducted to a shift of the critical reflection angle. The sensor's response after a specific binding of antigens to antibodies is discussed theoretically. In addition, an experimental sensitivity evaluation on the basis of several immunosensing experiments is presented. The obtained lower detection limit is 2 x 10(-2) nm in adlayer growth, equivalent to 12 pg/mm(2) of analyte coverage. This sensitivity is comparable to the performance of the surface plasmon resonance sensors or the grating coupler sensors. However, the ''critical'' sensor has some advantages. These are mainly the ease of fabrication and adjustment prior to a measurement, and the fact that for an experiment no metal layer has to be used.
引用
收藏
页码:295 / 304
页数:10
相关论文
共 12 条
[1]  
ANDRADE JD, 1985, SURFACE INTERFACIAL, V2
[2]   REAL-TIME ANALYSIS OF COMPETITIVE-BINDING USING GRATING COUPLER IMMUNOSENSORS FOR PESTICIDE DETECTION [J].
BIER, FF ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (02) :125-130
[3]   THE RESONANT MIRROR - A NOVEL OPTICAL BIOSENSOR FOR DIRECT SENSING OF BIOMOLECULAR INTERACTIONS .1. PRINCIPLE OF OPERATION AND ASSOCIATED INSTRUMENTATION [J].
CUSH, R ;
CRONIN, JM ;
STEWART, WJ ;
MAULE, CH ;
MOLLOY, J ;
GODDARD, NJ .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) :347-353
[4]   IMMUNOREACTIVITY OF ADSORBED ANTIHUMAN CHORIONIC-GONADOTROPIN STUDIED WITH AN OPTICAL WAVE-GUIDE INTERFEROMETRIC SENSOR [J].
HEIDEMAN, RG ;
KOOYMAN, RPH ;
GREVE, J .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (01) :33-43
[5]   PERFORMANCE OF A HIGHLY SENSITIVE OPTICAL WAVE-GUIDE MACH-ZEHNDER INTERFEROMETER IMMUNOSENSOR [J].
HEIDEMAN, RG ;
KOOYMAN, RPH ;
GREVE, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 10 (03) :209-217
[6]   VIBRATING MIRROR SURFACE-PLASMON RESONANCE IMMUNOSENSOR [J].
KOOYMAN, RPH ;
LENFERINK, ATM ;
EENINK, RG ;
GREVE, J .
ANALYTICAL CHEMISTRY, 1991, 63 (01) :83-85
[7]  
KOOYMAN RPH, 1995, CRC BIOSENSORS HDB
[8]   PRINCIPLES OF BIOSENSING WITH AN EXTENDED COUPLING MATRIX AND SURFACE-PLASMON RESONANCE [J].
LIEDBERG, B ;
LUNDSTROM, I ;
STENBERG, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) :63-72
[10]   SENSITIVITY OF INTEGRATED OPTICAL GRATING AND PRISM COUPLERS AS (BIO)CHEMICAL SENSORS [J].
LUKOSZ, W ;
TIEFENTHALER, K .