Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry

被引:87
作者
Garway-Heath, DF [1 ]
Poinoosawmy, D [1 ]
Wollstein, G [1 ]
Viswanathan, A [1 ]
Kamal, D [1 ]
Fontana, L [1 ]
Hitchings, RA [1 ]
机构
[1] Moorfields Eye Hosp, Glaucoma Unit, London EC1V 2PD, England
关键词
D O I
10.1136/bjo.83.6.664
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims-The development of imaging and measurement techniques has brought the prospect of greater objectivity in the measurement of optic disc features, and therefore better agreement between observers. The purpose of this study was to quantify and compare the variation between observers using two measurement devices. Methods-Optic disc photographs and images from the Heidelberg retina tomograph (HRT) of 30 eyes of 30 subjects were presented to six observers for analysis, and to one observer on five separate occasions. Agreement between observers was studied by comparing the analysis of each observer with the median result of the other five, and expressed as the mean difference and standard deviation of differences between the observer and the median. Inter- and intraobserver variation was calculated as a coefficient of variation (mean SD/mean x 100). Results-For planimetry, agreement between observers was dependent on observer experience, for the HRT it was independent. Agreement between observers (SD of differences as a percentage of the median) for optic disc area was 4.0% to 7.2% (planimetry) and 3.3% to 6.0% (HRT), for neuroretinal rim area it was 10.8% to 21.0% (planimetry) and 5.2% to 9.6% (HRT). The mean interobserver coefficient of variation for optic disc area was 8.1% (planimetry) and 4.4% (HRT), for neuroretinal rim area it was 16.3% (planimetry) and 8.1% (HRT), and (HRT only) for rim volume was 16.3%, and reference height 9.1%. HRT variability was greater for the software version 1.11 reference plane than for version 1.10. The intraobserver coefficient of variation for optic disc area was 1.5% (planimetry) and 2.4% (HRT), for neuroretinal rim area it was 4.0% (planimetry) and 4.5% (HRT). Conclusions-Variation between observers is greatly reduced by the HRT when compared with planimetry. However, levels of variation, which may be clinically significant, remain for variables that depend on the subjective drawing of the disc margin.
引用
收藏
页码:664 / 669
页数:6
相关论文
共 45 条
[1]  
AIRAKSINEN PJ, 1985, AM J OPHTHALMOL, V99, P1
[2]   RATE AND PATTERN OF NEURORETINAL RIM AREA DECREASE IN OCULAR HYPERTENSION AND GLAUCOMA [J].
AIRAKSINEN, PJ ;
TUULONEN, A ;
ALANKO, HI .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (02) :206-210
[3]   NEURORETINAL RIM AREA IN SUSPECTED GLAUCOMA AND EARLY CHRONIC OPEN-ANGLE GLAUCOMA - CORRELATION WITH PARAMETERS OF VISUAL FUNCTION [J].
BALAZSI, AG ;
DRANCE, SM ;
SCHULZER, M ;
DOUGLAS, GR .
ARCHIVES OF OPHTHALMOLOGY, 1984, 102 (07) :1011-1014
[4]   Influence of the contourline on the cup area using the Heidelberg Retina Tomograph [J].
BartzSchmidt, KU ;
JonescuCuypers, CP ;
Thumann, G ;
Frucht, J ;
Krieglstein, GK .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1996, 209 (05) :292-297
[5]   BIOMETRIC STUDY OF THE DISK CUP IN OPEN-ANGLE GLAUCOMA [J].
BETZ, P ;
CAMPS, F ;
COLLIGNONBRACH, J ;
LAVERGNE, G ;
WEEKERS, R .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1982, 218 (02) :70-74
[6]   VARIABILITY AND REPRODUCIBILITY OF OPTIC DISK TOPOGRAPHIC MEASUREMENTS WITH THE RODENSTOCK OPTIC-NERVE HEAD ANALYZER [J].
BISHOP, KI ;
WERNER, EB ;
KRUPIN, T ;
KOZART, DM ;
BECK, SR ;
NUNAN, FA ;
WAX, MB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 106 (06) :696-702
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   THE AREA OF THE NEURORETINAL RIM OF THE OPTIC-NERVE IN NORMAL EYES [J].
BRITTON, RJ ;
DRANCE, SM ;
SCHULZER, M ;
DOUGLAS, GR ;
MAWSON, DK .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1987, 103 (04) :497-504
[9]  
CAPRIOLI J, 1986, ARCH OPHTHALMOL-CHIC, V104, P1035
[10]   TEST-RETEST VARIABILITY OF TOPOGRAPHIC MEASUREMENTS WITH CONFOCAL SCANNING LASER TOMOGRAPHY IN PATIENTS WITH GLAUCOMA AND CONTROL SUBJECTS [J].
CHAUHAN, BC ;
LEBLANC, RP ;
MCCORMICK, TA ;
ROGERS, JB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (01) :9-15