Preanalytical variability: the dark side of the moon in laboratory testing

被引:293
作者
Lippi, G
Guidi, GC
Mattiuzzi, C
Plebani, M
机构
[1] Univ Verona, Dipartimento Sci Morfol Biomed, Ist Chim & Microscopia Clin, Osped Policlin GB Rossi, I-37134 Verona, Italy
[2] Azienda Osped Verona, Direz Med, Verona, Italy
[3] Univ Padua, Dipartimento Med Lab, Padua, Italy
关键词
error; laboratory instrumentation; laboratory testing; preanalytical variability;
D O I
10.1515/CCLM.2006.073
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Remarkable advances in instrument technology, automation and computer science have greatly simplified many aspects of previously tedious tasks in laboratory diagnostics, creating a greater volume of routine work, and significantly improving the quality of results of laboratory testing. Following the development and successful implementation of high-quality analytical standards, analytical errors are no longer the main factor influencing the reliability and clinical utilization of laboratory diagnostics. Therefore, additional sources of variation in the entire laboratory testing process should become the focus for further and necessary quality improvements. Errors occurring within the extra-analytical phases are still the prevailing source of concern. Accordingly, lack of standardized procedures for sample collection, including patient preparation, specimen acquisition, handling and storage, account for up to 93% of the errors currently encountered within the entire diagnostic process. The profound awareness that complete elimination of laboratory testing errors is unrealistic, especially those relating to extra-analytical phases that are harder to control, highlights the importance of good laboratory practice and compliance with the new accreditation standards, which encompass the adoption of suitable strategies for error prevention, tracking and reduction, including process redesign, the use of extra-analytical specifications and improved communication among caregivers.
引用
收藏
页码:358 / 365
页数:8
相关论文
共 53 条
[42]   Charting the course of medical laboratories in a changing environment [J].
Plebani, M .
CLINICA CHIMICA ACTA, 2002, 319 (02) :87-100
[43]  
Plebani M, 1997, CLIN CHEM, V43, P1348
[44]   Quality indicators and specifications for the extra-analytical phases in clinical laboratory management [J].
Ricós, C ;
García-Victoria, M ;
de la Fuente, B .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (06) :578-582
[45]  
Sharpe V. A., 1998, MED HARM HIST CONCEP
[46]  
Sieg Anke, 2005, Diabetes Technol Ther, V7, P174, DOI 10.1089/dia.2005.7.174
[47]  
Stahl M, 1998, CLIN CHEM, V44, P2195
[48]   The laboratory is a key partner in assuring patient safety [J].
Stankovic, AK .
CLINICS IN LABORATORY MEDICINE, 2004, 24 (04) :1023-+
[49]   Error budget calculations in laboratory medicine: linking the concepts of biological variation and allowable medical errors [J].
Stroobants, AK ;
Goldschmidt, HMJ ;
Plebani, M .
CLINICA CHIMICA ACTA, 2003, 333 (02) :169-176
[50]   Optical sensor systems for bioprocess monitoring [J].
Ulber, R ;
Frerichs, JG ;
Beutel, S .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (03) :342-348