Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients - Results from the PREPARE (Primary Prevention Parameters Evaluation) study

被引:418
作者
Wilkoff, Bruce L. [1 ]
Williamson, Brian D. [2 ]
Stern, Richard S. [3 ]
Moore, Stephen L. [4 ]
Lu, Fei [5 ]
Lee, Sung W. [6 ]
Birgersdotter-Green, Ulrika M. [7 ]
Wathen, Mark S. [8 ]
Van Gelder, Isabelle C. [9 ]
Heubner, Brooke M. [10 ]
Brown, Mark L. [10 ]
Holloman, Keith K. [10 ]
机构
[1] Case Western Reserve Univ, Cleveland Clin, Lerner Coll Med, Cleveland Clin Fdn, Cleveland, OH 44195 USA
[2] William Beaumont Hosp, Troy, MI USA
[3] Doctors Med Clin, San Pablo, CA USA
[4] EMH Reg Med Ctr, Elyria, OH USA
[5] Fairview Reg Med Ctr, Minneapolis, MN USA
[6] Washington Adventist Hosp, Takoma Pk, MD USA
[7] Univ Calif San Diego, San Diego, CA 92103 USA
[8] Vanderbilt Univ, Med Ctr, Nashville, TN USA
[9] Univ Groningen, Univ Med Ctr Groningen, Groningen, Netherlands
[10] Medtronic Inc, Minneapolis, MN USA
关键词
defibrillators; implantable; tachyarrhythmias; defibrillation; cardioversion;
D O I
10.1016/j.jacc.2008.05.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Our purpose was to demonstrate that strategically chosen implantable cardioverter-defibrillator (ICD) ventricular tachycardia (VT) or ventricular fibrillation (VF) detection and therapy parameters can reduce the combined incidence of device-delivered shocks, arrhythmic syncope, and untreated sustained symptomatic VT/VF (morbidity index). Background Strategically chosen ICD VT/VF detection and therapy parameters have been shown in previous studies to reduce the number of shocked episodes. In the PREPARE (Primary Prevention Parameters Evaluation) study, these prior strategies were combined with additional strategies specific to primary prevention patients. Methods The PREPARE study was a prospective, cohort-controlled study that analyzed 700 patients (biventricular [Bi-V] ICD and non-Bi-V ICD) with primary prevention indications for an ICD from 38 centers followed for 1 year. VT/VF was detected for rates >= 182 beats/min that were maintained for at least 30 of 40 beats. Antitachycardia pacing was programmed as the first therapy for regular rhythms with rates of 182 to 250 beats/min, and supraventricular tachycardia discriminators were used for rhythms <= 200 beats/min. The control cohort consisted of 689 primary prevention patients from the EMPIRIC (Comparison of Empiric to Physician-Tailored Programming of Implantable Cardioverter Defibrillators Trial) (non-Bi-V ICD, physician arm only) and MIRACLE ICD (Multicenter InSync Implantable Cardioversion Defibrillation Randomized Clinical Evaluation) (Bi-V ICD) trials for whom VT/VF detection and therapy programming were not controlled. Results The PREPARE programming significantly reduced the morbidity index incidence density (0.26 events/patient-year for PREPARE study patients vs. 0.69 control cohort, p = 0.003). The PREPARE study patients were less likely to receive a shock in the first year compared with control patients (9% vs. 17%, p < 0.01). The incidence of untreated VT and arrhythmic syncope was similar between the PREPARE study patients and the control cohort. Conclusions Strategically chosen VT/VF detection and therapy parameters can safely reduce shocks and other morbidities associated with ICD therapy in patients receiving an ICD for primary prevention indications. (PREPARE-Primary Prevention Parameters Evaluation; NCT00279279)
引用
收藏
页码:541 / 550
页数:10
相关论文
共 23 条
[11]   THE PROARRHYTHMIC POTENTIAL OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
PINSKI, SL ;
FAHY, GJ .
CIRCULATION, 1995, 92 (06) :1651-1664
[12]   Implantable cardioverter defibrillator events in patients with asymptomatic nonsustained ventricular tachycardia: Is device implantation justified? [J].
Russo, AM ;
Nayak, H ;
Verdino, R ;
Springman, J ;
Gerstenfeld, E ;
Hsia, H ;
Marchlinski, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (12) :2289-2295
[13]   Empirical versus tested antitachycardia pacing in implantable cardioverter defibrillators -: A prospective study including 200 patients [J].
Schaumann, A ;
von zur Mühlen, F ;
Herse, B ;
Gonska, BD ;
Kreuzer, H .
CIRCULATION, 1998, 97 (01) :66-74
[14]   Assessing the psychosocial impact of the ICD: A national survey of implantable cardioverter defibrillator health care providers [J].
Sears, SF ;
Todaro, JF ;
Urizar, G ;
Lewis, TS ;
Sirois, B ;
Wallace, R ;
Sotile, W ;
Curtis, AB ;
Conti, JB .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (06) :939-945
[15]   Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention Implantable cardioverter defibrillator patients - Results from the pacing fast VT REduces shock ThErapies (PainFREE Rx II) trial [J].
Sweeney, MO ;
Wathen, MS ;
Volosin, K ;
Abdalla, I ;
DeGroot, PJ ;
Otterness, MF ;
Stark, AJ .
CIRCULATION, 2005, 111 (22) :2898-2905
[16]   MORTALITY BENEFITS AND THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR [J].
SWEENEY, MO ;
RUSKIN, JN .
CIRCULATION, 1994, 89 (04) :1851-1858
[17]   Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators - Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results [J].
Wathen, MS ;
DeGroot, PJ ;
Sweeney, MO ;
Stark, AJ ;
Otterness, MF ;
Adkisson, WO ;
Canby, RC ;
Khalighi, K ;
Machado, C ;
Rubenstein, DS ;
Volosin, KJ .
CIRCULATION, 2004, 110 (17) :2591-2596
[18]   Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease [J].
Wathen, MS ;
Sweeney, MO ;
DeGroot, PJ ;
Stark, AJ ;
Koehler, JL ;
Chisner, MB ;
Machado, C ;
Adkisson, WO .
CIRCULATION, 2001, 104 (07) :796-801
[19]   Differences in tachyarrhythmia detection and implantable cardioverter defibrillator therapy by primary or secondary prevention indication in cardiac resynchronization therapy patients [J].
Wilkoff, BL ;
Hess, M ;
Young, J ;
Abraham, WT .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (09) :1002-1009
[20]  
Wilkoff BL, 2001, CIRCULATION, V103, P381