Preparation of Pt/polypyrrole-ferrocene hydrogen peroxide sensitive electrode for the use as a biosensor

被引:12
作者
Arslan, F [1 ]
Yasar, A
Kiliç, E
机构
[1] Gazi Univ, TR-06500 Ankara, Turkey
[2] Ankara Univ, TR-06100 Ankara, Turkey
关键词
polypyrrole; hydrogen peroxide; ferrocene;
D O I
10.1134/S1023193506020042
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A polypyrrole electrode with ferrocene mediator is prepared and its sensitivity to hydrogen peroxide is investigated. The polypyrrole is deposited upon a 0.5 cm(2) Pt plate by the polymerization of pyrrole by scanning the electrode potential between 0.0 and 0.9 V at a scan rate of 50 mV/s. The platinum/polypyrrole-ferrocene (Pt/PPy-Fc) electrode is prepared by adding ferrocene to the coverage medium. The electrode's sensitivity to hydrogen peroxide is investigated at room temperature using 0.025 M phosphate buffer at pH 7. The working potential is 0.7 V, the concentrations of pyrrole and ferrocene are 0.2 M and 10 mM. Polypyrrole was coated on the electrode surface within 26 cycles.
引用
收藏
页码:137 / 140
页数:4
相关论文
共 17 条
  • [1] Xanthine and hypoxanthine sensors based on xanthine oxidase immobilized in poly(mercapto-p-benzoquinone) film
    Arai, G
    Takahashi, S
    Yasumori, I
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 410 (02): : 173 - 179
  • [2] Determination of hydrogen peroxide in disinfectant solutions using a biosensor with two antagonist enzymes
    Campanella, L
    Favero, G
    Giancola, D
    Tomassetti, M
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) : 737 - 751
  • [3] Mediated biosensors
    Chaubey, A
    Malhotra, BD
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) : 441 - 456
  • [4] Immobilization of beef liver catalase on eggshell membrane for fabrication of hydrogen peroxide biosensor
    Choi, MMF
    Yiu, TP
    [J]. ENZYME AND MICROBIAL TECHNOLOGY, 2004, 34 (01) : 41 - 47
  • [5] New fructose biosensors utilizing a polypyrrole film and D-fructose 5-dehydrogenase immobilized by different processes
    Garcia, CAB
    Neto, GD
    Kubota, LT
    [J]. ANALYTICA CHIMICA ACTA, 1998, 374 (2-3) : 201 - 208
  • [6] Application of conducting polymers to biosensors
    Gerard, M
    Chaubey, A
    Malhotra, BD
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) : 345 - 359
  • [7] Gros P, 2000, ELECTROCHIM ACTA, V46, P643
  • [8] Disposable creatinine sensor based on thick-film hydrogen peroxide electrode system
    Kim, EJ
    Haruyama, T
    Yanagida, Y
    Kobatake, E
    Aizawa, M
    [J]. ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) : 225 - 231
  • [9] A three-enzyme microelectrode sensor for detecting purine release from central nervous system
    Llaudet, E
    Botting, NP
    Crayston, JA
    Dale, N
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (01) : 43 - 52
  • [10] Amperometric biosensors for sensing of hydrogen peroxide based on electron transfer between horseradish peroxidase and ferrocene as a mediator
    Nakabayashi, Y
    Yoshikawa, H
    [J]. ANALYTICAL SCIENCES, 2000, 16 (06) : 609 - 613