Immobilization of beef liver catalase on eggshell membrane for fabrication of hydrogen peroxide biosensor

被引:63
作者
Choi, MMF [1 ]
Yiu, TP [1 ]
机构
[1] Hong Kong Baptist Univ, Dept Chem, Kowloon Tong, Hong Kong, Peoples R China
关键词
catalase; eggshell membrane; hydrogen peroxide;
D O I
10.1016/j.enzmictec.2003.08.005
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A simple and low-cost hydrogen peroxide biosensor was fabricated using a beef liver catalase-immobilized eggshell membrane and an oxygen electrode. Catalase from beef liver extract was covalently immobilized on an eggshell membrane and subsequently covered the surface of an oxygen electrode. The detection scheme was based on the increase in dissolved oxygen content upon exposure to hydrogen peroxide solution. The increase in oxygen level was then monitored and related to the hydrogen peroxide concentration. The effects of enzyme loading, dissolved oxygen content, pH, phosphate buffer concentration and temperature on the biosensor have been studied in detail. The response and recovery times of the biosensor (t(95)) were 1 min, respectively. The detection limit based on 3sigma(b) was 3 muM and the relative standard deviation of the response was 1.28% (n=10) for a solution containing 0.3 mM of H2O2. The hydrogen peroxide biosensor demonstrated a reasonable long and stable shelf-life. It has been successfully applied to the determination of hydrogen peroxide concentration in some commercial samples. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 36 条
  • [1] SPECIFIC BIOELECTROCHEMICAL SENSOR FOR HYDROGEN-PEROXIDE
    AIZAWA, M
    KARUBE, I
    SUZUKI, S
    [J]. ANALYTICA CHIMICA ACTA, 1974, 69 (02) : 431 - 437
  • [2] GAS-SENSING INTERNAL ENZYME FIBER OPTIC BIOSENSOR FOR HYDROGEN-PEROXIDE
    ARNOLD, MA
    ZHOU, XG
    PETSCH, RS
    [J]. TALANTA, 1994, 41 (05) : 783 - 787
  • [3] A STUDY OF ORGANIC MATERIAL OF HENS-EGG SHELL
    BAKER, JR
    BALCH, DA
    [J]. BIOCHEMICAL JOURNAL, 1962, 82 (02) : 352 - +
  • [4] Hydrogen peroxide determination in pharmaceutical formulations and cosmetics using a new catalase biosensor
    Campanella, L
    Roversi, R
    Sammartino, MP
    Tomassetti, M
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (1-2) : 105 - 116
  • [5] An optical glucose biosensor with eggshell membrane as an enzyme immobilisation platform
    Choi, MMF
    Pang, WSH
    Xiao, D
    Wu, XJ
    [J]. ANALYST, 2001, 126 (09) : 1558 - 1563
  • [6] CHEMICALLY IMMOBILIZED ENZYME ELECTRODES FOR HYDROGEN-PEROXIDE DETERMINATION
    COSGROVE, M
    MOODY, GJ
    THOMAS, JDR
    [J]. ANALYST, 1988, 113 (12) : 1811 - 1815
  • [7] PEROXIDASE-MODIFIED CARBON-FIBER MICROELECTRODES IN FLOW-THROUGH DETECTION OF HYDROGEN-PEROXIDE AND ORGANIC PEROXIDES
    CSOREGI, E
    GORTON, L
    MARKOVARGA, G
    TUDOS, AJ
    KOK, WT
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (21) : 3604 - 3610
  • [8] The use of polymers coupled with metallised electrodes to allow H2O2 detection in the presence of electrochemical interferences
    Daly, DJ
    O'Sullivan, CK
    Guilbault, GG
    [J]. TALANTA, 1999, 49 (03) : 667 - 678
  • [9] PEROXIDASE AND HYDROGEN-PEROXIDE DETECTION BY A BIOENERGIZED METHOD
    DETOLEDO, SM
    HAUN, M
    BECHARA, EJH
    DURAN, N
    [J]. ANALYTICAL BIOCHEMISTRY, 1980, 105 (01) : 36 - 38
  • [10] Emerson D, 1996, BIOTECHNOL TECH, V10, P673