Immobilization of beef liver catalase on eggshell membrane for fabrication of hydrogen peroxide biosensor

被引:63
作者
Choi, MMF [1 ]
Yiu, TP [1 ]
机构
[1] Hong Kong Baptist Univ, Dept Chem, Kowloon Tong, Hong Kong, Peoples R China
关键词
catalase; eggshell membrane; hydrogen peroxide;
D O I
10.1016/j.enzmictec.2003.08.005
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A simple and low-cost hydrogen peroxide biosensor was fabricated using a beef liver catalase-immobilized eggshell membrane and an oxygen electrode. Catalase from beef liver extract was covalently immobilized on an eggshell membrane and subsequently covered the surface of an oxygen electrode. The detection scheme was based on the increase in dissolved oxygen content upon exposure to hydrogen peroxide solution. The increase in oxygen level was then monitored and related to the hydrogen peroxide concentration. The effects of enzyme loading, dissolved oxygen content, pH, phosphate buffer concentration and temperature on the biosensor have been studied in detail. The response and recovery times of the biosensor (t(95)) were 1 min, respectively. The detection limit based on 3sigma(b) was 3 muM and the relative standard deviation of the response was 1.28% (n=10) for a solution containing 0.3 mM of H2O2. The hydrogen peroxide biosensor demonstrated a reasonable long and stable shelf-life. It has been successfully applied to the determination of hydrogen peroxide concentration in some commercial samples. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 36 条
  • [21] Peroxidase enzyme sensor for on-line monitoring of disinfection processes in the food industry
    Moody, A
    Setford, S
    Saini, S
    [J]. ANALYST, 2001, 126 (10) : 1733 - 1739
  • [22] Nozaki O, 2000, LUMINESCENCE, V15, P137, DOI 10.1002/1522-7243(200005/06)15:3<137::AID-BIO576>3.0.CO
  • [23] 2-J
  • [24] AMPEROMETRIC INTERNAL ENZYME GAS-SENSING PROBE FOR HYDROGEN-PEROXIDE
    PAN, ST
    ARNOLD, MA
    [J]. ANALYTICA CHIMICA ACTA, 1993, 283 (02) : 663 - 671
  • [25] *PASC SCI, 1997, CI6542 PASC SCI, P28
  • [26] POSCH HE, 1989, MIKROCHIM ACTA, V1, P41
  • [27] *SIGM CHEM CO, 2000, SIGM CAT, P217
  • [28] CHEMILUMINOMETRIC ENZYME SENSORS FOR FLOW-INJECTION ANALYSIS
    SPOHN, U
    PREUSCHOFF, F
    BLANKENSTEIN, G
    JANASEK, D
    KULA, MR
    HACKER, A
    [J]. ANALYTICA CHIMICA ACTA, 1995, 303 (01) : 109 - 120
  • [29] Peroxidase-incorporated hydrophilic polythiophene electrode for the determination of hydrogen peroxide in acetonitrile
    Tatsuma, T
    Ariyama, K
    Oyama, N
    [J]. ANALYTICA CHIMICA ACTA, 1996, 318 (03) : 297 - 301
  • [30] Amperometric monitoring of hydrogen peroxide in workplace atmospheres by electrodes supported on ion-exchange membranes
    Toniolo, R
    Geatti, P
    Bontempelli, G
    Schiavon, G
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 514 (1-2): : 123 - 128