High mass-measurement accuracy and 100% sequence coverage of enzymatically digested bovine serum albumin from an ESI-FTICR mass spectrum

被引:82
作者
Bruce, JE [1 ]
Anderson, GA [1 ]
Wen, J [1 ]
Harkewicz, R [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Natl Lab, Environm & Mol Sci Lab, Separat & Mass Spectrometry Grp, Richland, WA 99352 USA
关键词
D O I
10.1021/ac990231s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of Fourier transform ion cyclotron resonance (FTICR) mass spectrometry to the analysis of polypeptide mixtures resulting from proteolytic digestion is described. A new 11.5-T FTICR mass spectrometer has been applied for the analysis of tryptic digestion mixtures of the protein bovine serum albumin (BSA), The improved cyclotron frequency stability;and reduced frequency shifts observed over a wide range of trapped ion population sizes provide the ability to signal average spectra without degrading mass measurement accuracy, requiring internal calibration or advanced data processing schemes to compensate for variations in ion cyclotron signals brought about by different population sizes. A total of 100 spectra were signal-averaged leading to the observation of a total of 123 isotope distributions with a signal-to-noise ratio greater than 3:1, From those distributions, 86 can be ascribed to tryptic fragments; of BSA on the basis of mass measurement errors of 10 ppm or less. Of these, 71 were within 2 ppm error limits corresponding to complete amino acid sequence cover;sge and an average error of 0.77 ppm. These results indicate that high-accuracy measurements are feasible for a large number of species detected simultaneously without the necessity for internal calibration and indicate the potential of such measurements, when combined with chromatographic separations, for facilitating more rapid identification of large numbers of proteins.
引用
收藏
页码:2595 / 2599
页数:5
相关论文
共 20 条
  • [1] ANDERSON GA, 1998, P 46 ASMS C MASS SPE, P1270
  • [2] Large molecule characterization based upon individual ion detection with electrospray ionization-FTICR mass spectrometry
    Bruce, JE
    Anderson, GA
    Udseth, HR
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (03) : 519 - 525
  • [3] Peptide and protein identification by matrix-assisted laser desorption ionization (MALDI) and MALDI-post-source decay time-of-flight mass spectrometry
    Chaurand, P
    Luetzenkirchen, F
    Spengler, B
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (02) : 91 - 103
  • [4] Routine part-per-million mass accuracy for high-mass ions: Space-charge effects in MALDI FT-ICR
    Easterling, ML
    Mize, TH
    Amster, IJ
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (03) : 624 - 632
  • [5] ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES
    FENN, JB
    MANN, M
    MENG, CK
    WONG, SF
    WHITEHOUSE, CM
    [J]. SCIENCE, 1989, 246 (4926) : 64 - 71
  • [6] Protein identification using mass spectrometric information
    Fenyö, D
    Qin, J
    Chait, BT
    [J]. ELECTROPHORESIS, 1998, 19 (06) : 998 - 1005
  • [7] High sensitivity analysis of proteins and peptides by capillary electrophoresis tandem mass spectrometry: Recent developments in technology and applications
    Figeys, D
    Aebersold, R
    [J]. ELECTROPHORESIS, 1998, 19 (06) : 885 - 892
  • [8] Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry at 11.5 tesla: Instrument design and initial results
    Gorshkov, MV
    Tolic, LP
    Udseth, HR
    Anderson, GA
    Huang, BM
    Bruce, JE
    Prior, DC
    Hofstadler, SA
    Tang, LA
    Chen, LZ
    Willett, JA
    Rockwood, AL
    Sherman, MS
    Smith, RD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (07) : 692 - 700
  • [9] HARKEWICZ R, UNPUB
  • [10] HILLENKAMP F, 1991, ANAL CHEM, V63, pA1193