Analysis of large compression loads on lumbar spine in flexion and in torsion using a novel wrapping element

被引:113
作者
Shirazi-Adl, A [1 ]
机构
[1] Ecole Polytech Montreal, Dept Mech Engn, Div Appl Mech, Montreal, PQ H3C 3A7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
compression; lumbar spine; flexion; axial torque; stiffness; wrapping element; stability;
D O I
10.1016/j.jbiomech.2004.11.022
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Axial compression on the spine could reach large values especially in lifting tasks which also involve large rotations. Experimental and numerical investigations on the spinal multi motion segments in presence of physiological compression loads cannot adequately be carried out due to the structural instability and artefact loads. To circumvent these problems, a novel wrapping cable element is used in a nonlinear finite element model of the lumbosacral spine (L1-S1) to investigate the role of moderate to large compression loads on the lumbar stiffness in flexion and axial moments/rotations. The compression loads up to 2700 N was applied with no instability or artefact loads. The lumbar stiffness substantially increased under compression force, flexion moment, and axial torque when applied alone. The presence of compression preloads significantly stiffened the load-displacement response under flexion and axial moments/rotations. This stiffening effect was much more pronounced under larger preloads and smaller moments/rotations. Compression preloads also increased intradiscal pressure, facet contact forces, and maximum disc fibre strain at different levels. Forces in posterior ligaments were, however, diminished with compression preload. The significant increase in spinal stiffness, hence, should be considered in biomechanical studies for accurate investigation of the load partitioning, system stability, and fixation systems/disc prostheses. (C) 2004 Published by Elsevier Ltd.
引用
收藏
页码:267 / 275
页数:9
相关论文
共 30 条
[1]
A TECHNIQUE FOR QUANTIFYING THE BENDING MOMENT ACTING ON THE LUMBAR SPINE INVIVO [J].
ADAMS, MA ;
DOLAN, P .
JOURNAL OF BIOMECHANICS, 1991, 24 (02) :117-126
[2]
PROLAPSED INTERVERTEBRAL-DISK - A HYPERFLEXION INJURY [J].
ADAMS, MA ;
HUTTON, WC .
SPINE, 1982, 7 (03) :184-191
[3]
GRADUAL DISK PROLAPSE [J].
ADAMS, MA ;
HUTTON, WC .
SPINE, 1985, 10 (06) :524-531
[4]
BRINCKMANN P, 1989, CLIN BIOMECHANICS S2, V4
[5]
In vitro axial preload application during spine flexibility testing: towards reduced apparatus-related artefacts [J].
Cripton, PA ;
Bruehlmann, SB ;
Orr, TE ;
Oxland, TR ;
Nolte, LP .
JOURNAL OF BIOMECHANICS, 2000, 33 (12) :1559-1568
[6]
THE INTERSEGMENTAL AND MULTISEGMENTAL MUSCLES OF THE LUMBAR SPINE - A BIOMECHANICAL MODEL COMPARING LATERAL STABILIZING POTENTIAL [J].
CRISCO, JJ ;
PANJABI, MM .
SPINE, 1991, 16 (07) :793-799
[7]
RISK-FACTORS IN LOW-BACK-PAIN - AN EPIDEMIOLOGICAL SURVEY [J].
FRYMOYER, JW ;
POPE, MH ;
CLEMENTS, JH ;
WILDER, DG ;
MACPHERSON, B ;
ASHIKAGA, T .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (02) :213-218
[8]
Physiological axial compressive preloads increase motion segment stiffness, linearity and hysteresis in all six degrees of freedom for small displacements about the neutral posture [J].
Gardner-Morse, MG ;
Stokes, IA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (03) :547-552
[9]
LARGE COMPRESSIVE PRELOADS DECREASE LUMBAR MOTION SEGMENT FLEXIBILITY [J].
JANEVIC, J ;
ASHTONMILLER, JA ;
SCHULTZ, AB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (02) :228-236
[10]
DYNAMICS OF HUMAN LUMBAR INTERVERTEBRAL JOINTS - EXPERIMENTAL AND FINITE-ELEMENT INVESTIGATIONS [J].
KASRA, M ;
SHIRAZIADL, A ;
DROUIN, G .
SPINE, 1992, 17 (01) :93-102