The use of poly(L-lactide) and RGD modified microspheres as cell carriers in a flow intermittency bioreactor for tissue engineering cartilage

被引:158
作者
Chen, Rui [1 ]
Curran, Stephen J. [1 ]
Curran, Judith M. [1 ]
Hunt, John A. [1 ]
机构
[1] Univ Liverpool, UK Ctr Tissue Engn, Liverpool L69 3GA, Merseyside, England
基金
英国工程与自然科学研究理事会; 英国生物技术与生命科学研究理事会;
关键词
poly(L-lactide); microspheres; cartilage; biodegradation;
D O I
10.1016/j.biomaterials.2006.04.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The use of biodegradable microcarriers as initial supports for tissue engineering has been demonstrated to be advantageous for maintaining a differentiated cell phenotype; the high surface area also allows rapid cell expansion. Poly L-lactide (PLLA) is a significant member of a group of polymers regarded as bioresorbable and has been widely used for manufacturing 3D scaffolds for tissue engineering. In this study, the hypothesis that PLLA microspheres could be surface modified using RGD peptide sequences to improve the cell adhesion and function of those cells in contact with PLLA was tested. Using this type of approach it may be possible to generate larger structures that contain a high cell number relative to the amount of polymer, whilst remaining free from mass transport limitations. PLLA microspheres were prepared using an oil-in-water solvent-evaporation technique and then an RGD-motif was incorporated onto the microspheres surface by conjugation to improve cell attachment and function. Both PLLA and GRGDSPK modified PLLA microspheres were used as cell microcarriers for chondrocytes cultured in a flow intermittency bioreactor. At the same time, the degradation of the microspheres has been studied after 7, 14, 21, 28 35, 49 and 56 days. The molecular weight of the PLLA microspheres was determined by Gel Permeation Chromatography. The morphology was assessed by scanning electron microscopy, and the thermal properties determined by Differential Scanning Calorimetry. It was demonstrated that the RGD modified and pure PLLA microspheres degraded gradually at a steady rate over the experimental period, which would provide a controlled degradation profile, both could serve as cell microcarriers because of their thermal and mechanical stabilities. The microspheres with RGD surface modification enhanced cell adhesion and increased the cell numbers in the microspheres aggregates. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4453 / 4460
页数:8
相关论文
共 33 条
[1]
MECHANISMS OF POLYMER DEGRADATION IN IMPLANTABLE DEVICES .2. POLY(DL-LACTIC ACID) [J].
ALI, SAM ;
DOHERTY, PJ ;
WILLIAMS, DF .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (11) :1409-1418
[2]
Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid polyglycolic acid copolymers [J].
Athanasiou, KA ;
Niederauer, GG ;
Agrawal, CM .
BIOMATERIALS, 1996, 17 (02) :93-102
[3]
Basic science of articular cartilage repair [J].
Athanasiou, KA ;
Shah, AR ;
Hernandez, RJ ;
LeBaron, RG .
CLINICS IN SPORTS MEDICINE, 2001, 20 (02) :223-+
[4]
IN-VIVO DEGRADATION AND BIOCOMPATIBILITY STUDY OF IN-VITRO PRE-DEGRADED AS-POLYMERIZED POLYLACTIDE PARTICLES [J].
BERGSMA, JE ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G ;
DEBRUIJN, WC ;
PENNINGS, AJ .
BIOMATERIALS, 1995, 16 (04) :267-274
[5]
BUTLER M, 1988, ANIMAL CELL BIOTECHN, V3, P284
[6]
DEGRADATION OF HIGH-MOLECULAR-WEIGHT POLY(L-LACTIDE) IN ALKALINE-MEDIUM [J].
CAM, D ;
HYON, SH ;
IKADA, Y .
BIOMATERIALS, 1995, 16 (11) :833-843
[7]
Carver SE, 1999, BIOTECHNOL BIOENG, V65, P274
[8]
Biodegradable PLGA microcarriers for injectable delivery of chondrocytes: Effect of surface modification on cell attachment and function [J].
Chun, KW ;
Yoo, HS ;
Yoon, JJ ;
Park, TG .
BIOTECHNOLOGY PROGRESS, 2004, 20 (06) :1797-1801
[9]
Effects of solvent evaporation rate on the properties of protein-loaded PLLA and PDLLA microspheres fabricated by emulsion-solvent evaporation process [J].
Chung, TW ;
Huang, YY ;
Tsai, YL ;
Liu, YZ .
JOURNAL OF MICROENCAPSULATION, 2002, 19 (04) :463-471
[10]
Expansion of human chondrocytes in an intermittent stirred flow bioreactor, using modified biodegradable microspheres [J].
Curran, SJ ;
Chen, R ;
Curran, JM ;
Hunt, JA .
TISSUE ENGINEERING, 2005, 11 (9-10) :1312-1322