Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring

被引:513
作者
Droitcour, AD [1 ]
Boric-Lubecke, O
Lubecke, VM
Lin, JS
Kovacs, GTA
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Bell Labs, Lucent Technol, Murray Hill, NJ 07974 USA
[3] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
[4] Stanford Univ, Dept Med, Stanford, CA 94305 USA
基金
美国国家航空航天局; 美国国家科学基金会;
关键词
BiCMOS analog integrated circuits; biomedical monitoring; CMOS analog integrated circuits; continuous-wave (CW) radar; Doppler radar; homodyne detection; micro wave integrated circuits; phase noise; radar clutter; range correlation; remote sensing;
D O I
10.1109/TMTT.2004.823552
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Direct-conversion microwave Doppler-radar transceivers have been fully integrated in 0.25-mum silicon CMOS and BiCMOS technologies. These chips, operating At 1.6 and 2.4 GHz, have detected movement due to heartbeat and respiration 50 cm from the subject, which may be useful in infant and adult apnea monitoring. The range-correlation effect on residual phase noise is a critical factor when detecting small phase fluctuations with a high-phase-noise on-chip oscillator. Phase-noise reduction due to range correlation was experimentally evaluated, and the measured residual phase noise was within 5 dB of predicted values on average. In a direct-conversion receiver, the phase relationship between the received signal and the local oscillator has a significant effect on the demodulation sensitivity, and the null points can be avoided with a quadrature (I/Q) receiver. In this paper, measurements that highlight the performance benefits of an I/Q receiver are presented. While the accuracy of the heart rate measured with the single-channel chip ranges from 40% to 100%, depending on positioning, the quadrature chip accuracy is always better than 80%.
引用
收藏
页码:838 / 848
页数:11
相关论文
共 19 条
[1]  
ALUKKANEN RMT, 1998, J SPORTS SCI, V16, pS3
[2]   DCS 1800 base station receiver integrated in 0.25μm CMOS [J].
Boric-Lubecke, O ;
Lin, JS ;
Gould, P .
2002 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2002, :1049-1052
[3]  
Budge M. C. Jr., 1993, Proceedings IEEE Southeastcon '93 (Cat. No.93CH3295-3), DOI 10.1109/SECON.1993.465731
[4]   Metabolism of the hamster pancreatic carcinogen methyl-2-oxopropylnitrosamme by hamster liver and pancreas [J].
Chen, SC ;
Wang, XJ ;
Zhou, L ;
Kolar, C ;
Lawson, TA ;
Mirvish, SS .
INTERNATIONAL JOURNAL OF PANCREATOLOGY, 2000, 27 (02) :105-112
[5]  
Droitcour A, 2001, IEEE MTT S INT MICR, P175, DOI 10.1109/MWSYM.2001.966866
[6]  
Droitcour AD, 2003, IEEE MTT S INT MICR, P1945, DOI 10.1109/MWSYM.2003.1210539
[7]  
DROITCOUR AD, 2002, IEEE INT SOL STAT CI, V1, P348
[8]   PORTABLE RECORDING IN THE ASSESSMENT OF OBSTRUCTIVE SLEEP-APNEA [J].
FERBER, R ;
MILLMAN, R ;
COPPOLA, M ;
FLEETHAM, J ;
MURRAY, CF ;
IBER, C ;
MCCALL, V ;
NINOMURCIA, G ;
PRESSMAN, M ;
SANDERS, M ;
STROHL, K ;
VOTTERI, B ;
WILLIAMS, A .
SLEEP, 1994, 17 (04) :378-392
[9]   Annual summary of vital statistics: 2000 [J].
Hoyert, DL ;
Freedman, MA ;
Strobino, DM ;
Guyer, B .
PEDIATRICS, 2001, 108 (06) :1241-1255
[10]   Validation of a new respiratory inductive plethysmograph [J].
Leino, K ;
Nunes, S ;
Valta, P ;
Takala, J .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (01) :104-111