Monitoring interposition graft venous pressures at higher blood-flow rates improves sensitivity in predicting graft failure

被引:10
作者
Agarwal, R
Davis, JL
机构
[1] Indiana Univ, Sch Med, Indianapolis, IN 46202 USA
[2] Richard L Roudebush Vet Affairs Med Ctr, Indianapolis, IN 46202 USA
关键词
angioaccess; survival; hemodialysis; monitoring;
D O I
10.1016/S0272-6386(99)70345-8
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Monitoring the patency of hemodialysis interposition grafts is recommended to improve graft survival. Which blood flows best predict graft survival is not known. We monitored venous pressures in 32 dialysis patients over a median of 252 days at variable flow rates of the blood pump (Qb). Venous pressure trends (VPTs), maximum venous pressure (MVP), and the variability of venous pressure (percent coefficient of variation) were calculated. Kaplan-Meier curves were constructed from the time of the end of VPT monitoring to time to failure, defined as angioplasty, clotting, or surgical revision. Risk for graft failure for each 10-mm Hg increase in venous pressure was calculated by the Cox proportional hazards model. There were 12 graft failures, but no failures in 12 fistulas over the course of the study. The variability in venous pressure was less at greater Qbs. For grafts, VPTs were predictive of event only when calculated for abs greater than 100 mL/min. At Qbs of 400 mL/min, there was a 70% risk for graft failure with each 10-mm Hg increase in VPT. The risk for graft failure increased between 28% and 44% for each 10-mm Hg increase in MVP at all Qbs. MVP of 230 mm Hg at a Qb of 400 mL/min provided the best efficiency of test performance. Dialysis venous chamber pressure monitoring is a useful test to predict graft stenosis or thrombosis. There is a substantial variability in venous pressures in the same patient that reduces with increasing Qbs. Venous pressure monitoring at greater Qbs provides a more sensitive method for predicting access failure, (C) 1999 by the National Kidney Foundation Inc.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 11 条
  • [1] [Anonymous], 1997, Am J Kidney Dis, V30, pS150
  • [2] Besarab A, 1998, J AM SOC NEPHROL, V9, P284
  • [3] UTILITY OF INTRA-ACCESS PRESSURE MONITORING IN DETECTING AND CORRECTING VENOUS OUTLET STENOSES PRIOR TO THROMBOSIS
    BESARAB, A
    SULLIVAN, KL
    ROSS, RP
    MORITZ, MJ
    [J]. KIDNEY INTERNATIONAL, 1995, 47 (05) : 1364 - 1373
  • [4] The prevention of access failure - Pressure monitoring
    Besarab, A
    Frinak, S
    [J]. ASAIO JOURNAL, 1998, 44 (01) : 35 - 37
  • [5] Besarab A, 1997, ASAIO J, V43, pM539
  • [6] Hemodialysis access failure: A call to action
    Hakim, R
    Himmelfarb, J
    [J]. KIDNEY INTERNATIONAL, 1998, 54 (04) : 1029 - 1040
  • [7] SURVIVAL-DATA .17.
    HEALY, MJR
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1995, 73 (04) : 374 - 377
  • [8] Hemodialysis access blood flow rates can be measured by a differential conductivity technique and are predictive of access clotting
    Lindsay, RM
    Blake, PG
    Malek, P
    Posen, G
    Martin, B
    Bradfield, E
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 30 (04) : 475 - 482
  • [9] PREVENTION OF HEMODIALYSIS FISTULA THROMBOSIS - EARLY DETECTION OF VENOUS STENOSES
    SCHWAB, SJ
    RAYMOND, JR
    SAEED, M
    NEWMAN, GE
    DENNIS, PA
    BOLLINGER, RR
    [J]. KIDNEY INTERNATIONAL, 1989, 36 (04) : 707 - 711
  • [10] TRANS-LUMINAL ANGIOPLASTY OF VENOUS STENOSES IN POLYTETRAFLUOROETHYLENE VASCULAR ACCESS GRAFTS
    SCHWAB, SJ
    SAEED, M
    SUSSMAN, SK
    MCCANN, RL
    STICKEL, DL
    [J]. KIDNEY INTERNATIONAL, 1987, 32 (03) : 395 - 398