On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies

被引:155
作者
Di Bella, EVR
Parker, DL
Sinusas, AJ
机构
[1] Univ Utah, Dept Radiol, Salt Lake City, UT 84132 USA
[2] Yale Univ, Dept Internal Med, New Haven, CT USA
[3] Yale Univ, Dept Diagnost Radiol, New Haven, CT 06510 USA
关键词
dark rim; artifact; filtering; myocardial perfusion imaging; dynamic contrast MRI;
D O I
10.1002/mrm.20666
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dark band or rim along parts of the subendocardial border of the left ventricle (LV) and the myocardium has been noticed in some dynamic contrast-enhanced MR perfusion studies. The artifact is thought to be clue to susceptibility effects from the gadolinium bolus, motion, or resolution, or a combination of these. Here motionless ex vivo hearts in which the cavity was filled with gadolinium are used to show that dark rim artifacts can be consistent with resolution effects alone.
引用
收藏
页码:1295 / 1299
页数:5
相关论文
共 14 条
[1]   A method to reduce the Gibbs ringing artifact in MRI scans while keeping tissue boundary integrity [J].
Archibald, R ;
Gelb, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (04) :305-319
[2]   Imaging of myocardial perfusion with magnetic resonance [J].
Barkhausen, J ;
Hunold, P ;
Jochims, M ;
Debatin, JF .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (06) :750-757
[3]  
DIBELLA EVR, 2005, P 8 ANN SOC CARD MAG, V7, P279
[4]   Multislice first-pass myocardial perfusion imaging: Comparison of saturation recovery (SR)-TrueFISP-two-dimensional (2D) and SR-TurboFLASH-2D pulse sequences [J].
Fenchel, M ;
Helber, U ;
Simonetti, OP ;
Stauder, NI ;
Kramer, U ;
Nguyen, CN ;
Finn, JP ;
Claussen, CD ;
Miller, S .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (05) :555-563
[5]   Magnetic resonance versus radionuclide pharmacological stress perfusion imaging for flow-limiting stenoses of varying severity [J].
Lee, DC ;
Simonetti, OP ;
Harris, KR ;
Holly, TA ;
Judd, RM ;
Wu, E ;
Klocke, FJ .
CIRCULATION, 2004, 110 (01) :58-65
[6]   Flow effects in balanced steady state free precession imaging [J].
Markl, M ;
Alley, MT ;
Elkins, CJ ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) :892-903
[7]   Reduced myocardial perfusion reserve and transmural perfusion gradient in heart transplant arteriopathy assessed by magnetic resonance imaging [J].
Muehling, OM ;
Wilke, NM ;
Panse, P ;
Jerosch-Herold, M ;
Wilson, BV ;
Wilson, RF ;
Miller, LW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (06) :1054-1060
[8]   Subclavian MR arteriography: Reduction of susceptibility artifact with short echo time and dilute gadopentetate dimeglumine [J].
Neimatallah, MA ;
Chenevert, TL ;
Carlos, RC ;
Londy, FJ ;
Dong, Q ;
Prince, MR ;
Kim, HM .
RADIOLOGY, 2000, 217 (02) :581-586
[9]   GIBBS ARTIFACT REMOVAL IN MAGNETIC-RESONANCE-IMAGING [J].
PARKER, DL ;
GULLBERG, GT ;
FREDERICK, PR .
MEDICAL PHYSICS, 1987, 14 (04) :640-645
[10]  
Schwitter J, 2001, CIRCULATION, V103, P2230