Imaging of myocardial perfusion with magnetic resonance

被引:56
作者
Barkhausen, J
Hunold, P
Jochims, M
Debatin, JF
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45122 Essen, Germany
[2] Elisabeth Hosp Essen, Dept Cardiol, Essen, Germany
关键词
magnetic resonance imaging; myocardial perfusion; contrast agents; pulse sequences; coronary artery disease;
D O I
10.1002/jmri.20073
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Coronary artery disease (CAD) is currently the leading cause of death in developed nations. Reflecting the complexity of cardiac function and morphology, noninvasive diagnosis of CAD represents a major challenge for medical imaging. Although coronary artery stenoses can be depicted with magnetic resonance (MR) and computed tomography (CT) techniques, its functional or hemodynamic impact frequently remains elusive. Therefore, there is growing interest in other, target organ-specific parameters such as myocardial function at stress and first-pass myocardial perfusion imaging to assess myocardial blood flow. This review explores the pathophysiologic background, recent technical developments, and current clinical status of first-pass MR imaging (MRI) of myocardial perfusion.
引用
收藏
页码:750 / 757
页数:8
相关论文
共 52 条
[1]   Dobutamine induced myocardial perfusion reserve index with cardiovascular MR in patients with coronary artery disease [J].
Al-Saadi, N ;
Gross, M ;
Paetsch, I ;
Schnackenburg, B ;
Bornstedt, A ;
Fleck, E ;
Nagel, E .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2002, 4 (04) :471-480
[2]  
Al-Saadi N, 2001, Z KARDIOL, V90, P824, DOI 10.1007/s003920170081
[3]  
ARAI E, 2000, TOP MAGN RESON IMAG, V11, P383
[4]   EFFECT OF PERFUSION-PRESSURE DISTAL TO A CORONARY STENOSIS ON TRANSMURAL MYOCARDIAL BLOOD-FLOW [J].
BACHE, RJ ;
SCHWARTZ, JS .
CIRCULATION, 1982, 65 (05) :928-935
[5]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[6]   Magnetic resonance myocardial first-pass perfusion imaging: Parameter optimization for signal response and cardiac coverage [J].
Bertschinger, KM ;
Nanz, D ;
Buechi, M ;
Luescher, TF ;
Marincek, B ;
von Schulthess, GK ;
Schwitter, J .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :556-562
[7]   Optimal characterization of myocardial perfusion with AngioMARK [J].
Bluemke, DA ;
Kraitchman, DL ;
Heldman, A ;
Chin, BB ;
Steinert, C .
ACADEMIC RADIOLOGY, 2002, 9 :S78-S78
[8]   CORONARY RESERVE - CONCEPT AND PHYSIOLOGICAL VARIATIONS [J].
BOURDARIAS, JP .
EUROPEAN HEART JOURNAL, 1995, 16 :2-6
[9]   A myocardial perfusion reserve index in humans using first-pass contrast-enhanced magnetic resonance imaging [J].
Cullen, JHS ;
Horsfield, MA ;
Reek, CR ;
Cherryman, GR ;
Barnett, DB ;
Samani, NJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (05) :1386-1394
[10]   ASSESSMENT OF CORONARY-ARTERY DISEASE SEVERITY BY POSITRON EMISSION TOMOGRAPHY - COMPARISON WITH QUANTITATIVE ARTERIOGRAPHY IN 193 PATIENTS [J].
DEMER, LL ;
GOULD, KL ;
GOLDSTEIN, RA ;
KIRKEEIDE, RL ;
MULLANI, NA ;
SMALLING, RW ;
NISHIKAWA, A ;
MERHIGE, ME .
CIRCULATION, 1989, 79 (04) :825-835