MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study

被引:284
作者
Barkhausen, J
Ruehm, SG
Goyen, M
Buck, T
Laub, G
Debatin, JF
机构
[1] Univ Hosp Essen, Dept Diagnost Radiol, D-45122 Essen, Germany
[2] Univ Hosp Essen, Dept Cardiol, D-45122 Essen, Germany
[3] Siemens Med Syst, Erlangen, Germany
关键词
heart; MR; ventricles; volume; magnetic resonance (MR); cine study; pulse sequences; volume measurement;
D O I
10.1148/radiology.219.1.r01ap12264
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Short- and long-axis cine magnetic resonance (MR) images were obtained with a standard fast low-angle shot, or FLASH, sequence and a first generation true fast imaging with steady-state precession (FISP) sequence on a 1.5-T MR imager. Contrast-to-noise ratios and volumetric left ventricular measurements were compared for manual and automatic segmentation. True FISP images were associated with significantly (P <.01) higher contrast-to-noise ratios and allowed better detection of the endocardial border. True FISP images were provided with short acquisition times and excellent contrast between the myocardium and the ventricular lumen.
引用
收藏
页码:264 / 269
页数:6
相关论文
共 20 条
[1]  
Alley MT, 1999, JMRI-J MAGN RESON IM, V9, P751, DOI 10.1002/(SICI)1522-2586(199905)9:5<751::AID-JMRI21>3.0.CO
[2]  
2-7
[3]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[4]   AUTOMATED MYOCARDIAL EDGE-DETECTION FROM BREATH-HOLD CINE-MR IMAGES - EVALUATION OF LEFT-VENTRICULAR VOLUMES AND MASS [J].
BALDY, C ;
DOUEK, P ;
CROISILLE, P ;
MAGNIN, IE ;
REVEL, D ;
AMIEL, M .
MAGNETIC RESONANCE IMAGING, 1994, 12 (04) :589-598
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Segmented K-space cine breath-hold cardiovascular MR imaging .1. Principles and technique [J].
Bluemke, DA ;
Boxerman, JL ;
Atalar, E ;
McVeigh, ER .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (02) :395-400
[7]  
CHIEN D, 1991, Magnetic Resonance Quarterly, V7, P31
[8]   CARDIAC EJECTION FRACTION - PHANTOM STUDY COMPARING CINE MR IMAGING, RADIONUCLIDE BLOOD POOL IMAGING, AND VENTRICULOGRAPHY [J].
DEBATIN, JF ;
NADEL, SN ;
PAOLINI, JF ;
SOSTMAN, HD ;
COLEMAN, RE ;
EVANS, AJ ;
BEAM, C ;
SPRITZER, CE ;
BASHORE, TM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02) :135-142
[9]  
FANG W, 2000, P 8 ANN M ISMRM DENV, P308
[10]   AUTOMATED IDENTIFICATION OF LEFT-VENTRICULAR BORDERS FROM SPIN-ECHO MAGNETIC-RESONANCE IMAGES - EXPERIMENTAL AND CLINICAL FEASIBILITY STUDIES [J].
FLEAGLE, SR ;
THEDENS, DR ;
EHRHARDT, JC ;
SCHOLZ, TD ;
SKORTON, DJ .
INVESTIGATIVE RADIOLOGY, 1991, 26 (04) :295-303