The efficacy of different commercially available demineralized bone matrix substances in an athymic rat model

被引:59
作者
Lee, YP [1 ]
Jo, M [1 ]
Luna, M [1 ]
Chien, B [1 ]
Lieberman, JR [1 ]
Wang, JC [1 ]
机构
[1] Univ Calif Los Angeles, Dept Orthopaed Surg, Los Angeles, CA 90095 USA
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2005年 / 18卷 / 05期
关键词
athymic rat; demineralized bone matrix; intertransverse fusion;
D O I
10.1097/01.bsd.0000175696.66049.f7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Bone graft substitutes have been developed because there is a limited supply of autogenous graft and the harvesting of iliac crest bone graft is associated with significant morbidity. Currently, there are a number of different commercially available demineralized bone matrix (DBM) products available that have been prepared by different methods and have different carriers. The objective of this study was to compare eight different commercially available DBM products. Methods: Eight different DBMs were used to attempt a spinal fusion between the L4-L5 transverse processes in athymic rats. There were 10 rats in each group, and 5 rats were killed at both 4 and 8 weeks. Radiographic and histologic analyses were performed. Manual palpation testing was also performed. Results: At 4 weeks, Osteofil Paste had the highest radiographic scores, whereas Grafton Putty had the best radiographic scores at 8 weeks. Conversely, the spines implanted with Allomatrix had the lowest radiographic scores at both 4 and 8 weeks. In regard to forming a spinal fusion confirmed by manual palpation, Osteofil Paste was the most effective at 4 weeks, whereas Grafton Flex and Grafton Putty had the highest rate of fusion at 8 weeks. Conversely, the lowest rates of fusion were seen in the Allomatrix and Grafton Crunch groups. Statistical analysis showed that there were significant differences among the groups seen on radiographs and by manual palpation. Qualitative differences could be appreciated between the groups histologically. Conclusion: Significant differences exist among commercially available DBMs in forming a spinal fusion in an athymic rat.
引用
收藏
页码:439 / 444
页数:6
相关论文
共 19 条
[11]  
KELLY CM, 2001, CLIN ORTHOP RELAT R, V382, P42
[12]   Optimizing human demineralized bone matrix for clinical application [J].
Maddox, E ;
Zhan, M ;
Mundy, GR ;
Drohan, WN ;
Burgess, WH .
TISSUE ENGINEERING, 2000, 6 (04) :441-448
[13]   Experimental posterolateral lumbar spinal fusion with a demineralized bone matrix gel [J].
Morone, MA ;
Boden, SD .
SPINE, 1998, 23 (02) :159-167
[14]   Bone grafting for spinal fusion [J].
Sandhu, HS ;
Grewal, HS ;
Parvataneni, H .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (04) :685-+
[15]  
Sassard WR, 2000, ORTHOPEDICS, V23, P1059
[16]   A comparative analysis of fusion rates and donor-site morbidity for autogeneic rib and iliac crest bone grafts in posterior cervical fusions [J].
Sawin, PD ;
Traynelis, VC ;
Menezes, AH .
JOURNAL OF NEUROSURGERY, 1998, 88 (02) :255-265
[17]   DONOR SITE PAIN FROM THE ILIUM - A COMPLICATION OF LUMBAR SPINE FUSION [J].
SUMMERS, BN ;
EISENSTEIN, SM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (04) :677-680
[18]   Donor-site morbidity with use of vascularized autogenous fibular grafts [J].
Vail, TP ;
Urbaniak, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (02) :204-211
[19]   Effect of regional gene therapy with bone morphogenetic protein-2-producing bone marrow cells on spinal fusion in rats [J].
Wang, JC ;
Kanim, LEA ;
Yoo, S ;
Campbell, PA ;
Berk, AJ ;
Lieberman, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :905-911