Laboratory and clinical evaluation of assays for beta-hydroxybutyrate

被引:30
作者
Porter, WH
Yao, HH
Karounos, DG
机构
[1] UNIV KENTUCKY,MED CTR,DEPT INTERNAL MED,LEXINGTON,KY 40536
[2] VET AFFAIRS MED CTR,LEXINGTON,KY
关键词
acetoacetate; diabetic ketoacidosis; assay evaluation; beta-hydroxybutyrate; interference;
D O I
10.1093/ajcp/107.3.353
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
We have performed a two-part evaluation of assays for beta-hydroxybutyrate (beta HB). In Part I, we evaluated the analytical acceptability of a dry film, self-contained analyzer for beta HB measurement (KetoSite; GDS Diagnostics, Elkhart, Ind). The assay response is linear and between-day imprecision is acceptable. Acetoacetate (AcAc) interferes severely with this assay. This interference could be minimized by dilution of serum before the assay. With this predilution protocol, KetoSite beta HB results compare favorably with an automated Sigma (St. Louis, Mo) beta HB assay. In Part II, we compared the clinical utility of beta HB measurements (Sigma) with the qualitative measurement of ketones using the nitroprusside test (Acetest; Bayer, Elkhart, Ind) for the diagnosis and management of diabetic ketoacidosis (DKA). Test results for both assays were abnormal for all patients with DKA on admission. However, frequent monitoring with either test during the management of uncomplicated DKA added little if any additional clinical information over routine measurements of serum glucose and total carbon dioxide.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 16 条
[11]  
OZAKI N, 1993, SURGERY, V113, P403
[12]  
SACKS DB, 1994, TIETZ TXB CLIN CHEM, P971
[13]   RELATIONSHIP OF BLOOD ACETOACETATE AND 3-HYDROXYBUTYRATE IN DIABETES [J].
STEPHENS, JM ;
SULWAY, MJ ;
WATKINS, PJ .
DIABETES, 1971, 20 (07) :485-&
[14]   Ketone body ratios of the superior and inferior vena cava and of pulmonary arterial blood compared to that of arterial blood: Central venous ketone body ratio as a substitute for the arterial ketone body ratio [J].
Terada, Y ;
Eguchi, Y ;
Chang, YJ ;
Tabata, R ;
Sakumoto, H ;
Takehiro, O ;
Uno, S ;
Ozawa, K .
CLINICA CHIMICA ACTA, 1996, 247 (1-2) :81-88
[15]   CLINICAL UTILITY OF BETA-HYDROXYBUTYRATE DETERMINED BY REFLECTANCE METER IN THE MANAGEMENT OF DIABETIC-KETOACIDOSIS [J].
UMPIERREZ, GE ;
WATTS, NB ;
PHILLIPS, LS .
DIABETES CARE, 1995, 18 (01) :137-138
[16]   EVALUATION OF THE LIVER GRAFT BEFORE PROCUREMENT - SIGNIFICANCE OF ARTERIAL KETONE-BODY RATIO IN BRAIN-DEAD PATIENTS [J].
YAMAOKA, Y ;
TAKI, Y ;
GUBERNATIS, G ;
NAKATANI, T ;
OKAMOTO, R ;
YAMAMOTO, Y ;
ISHIKAWA, Y ;
RINGE, B ;
BUNZENDAHL, H ;
OELLERICH, M ;
KOBAYASHI, K ;
OZAWA, K ;
PICHLMAYR, R .
TRANSPLANT INTERNATIONAL, 1990, 3 (02) :78-81