Microfabricated porous membrane structure for sample concentration and electrophoretic analysis

被引:209
作者
Khandurina, J [1 ]
Jacobson, SC [1 ]
Waters, LC [1 ]
Foote, RS [1 ]
Ramsey, JM [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
关键词
D O I
10.1021/ac981161c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfabricated injection valve incorporating a porous membrane structure is reported that enables electrokinetic concentration of DNA samples using homogeneous buffer conditions followed by injection into a channel for electrophoretic analysis. The porous membrane was incorporated in the microchannel manifold by having two channels separated from each other by 3-12 mu m and connected by a thin porous silicate layer. This design allows the passage of current to establish an electrical connection between the separated channels but prevents large molecules, e.g., DNA, from traversing the membrane. Concentrated DNA can be injected into the separation channel and electrophoretically analyzed. Experiments exhibit a nonlinear increase in concentration with time, and DNA fragments can be concentrated up to 2 orders of magnitude as shown by comparison of peak intensities for analysis performed with and without concentration.
引用
收藏
页码:1815 / 1819
页数:5
相关论文
共 31 条
[1]   ANALYSIS OF DILUTE PEPTIDE SAMPLES BY CAPILLARY ZONE ELECTROPHORESIS [J].
AEBERSOLD, R ;
MORRISON, HD .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :79-88
[2]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[3]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[4]   Counting single chromophore molecules for ultrasensitive analysis and separations on microchip devices [J].
Fister, JC ;
Jacobson, SC ;
Davis, LM ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :431-437
[5]   Integrated capillary electrophoresis devices with an efficient postcolumn reactor in planar quartz and glass chips [J].
Fluri, K ;
Fitzpatrick, G ;
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4285-4290
[6]   ON-COLUMN TRANSIENT AND COUPLED COLUMN ISOTACHOPHORETIC PRECONCENTRATION OF PROTEIN SAMPLES IN CAPILLARY ZONE ELECTROPHORESIS [J].
FORET, F ;
SZOKO, E ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :3-12
[7]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[8]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[9]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[10]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61