Dynamic imaging with MRI contrast agents: quantitative considerations

被引:60
作者
Shapiro, Mikhail G.
Atanasijevic, Tatjana
Faas, Henryk
Westmeyer, Gil G.
Jasanoff, Alan [1 ]
机构
[1] MIT, Dept Nucl Sci & Engn, Cambridge, MA 02139 USA
[2] MIT, Div Biol Engn, Cambridge, MA 02139 USA
[3] MIT, Dept Brain & Cognit Sci, Cambridge, MA 02139 USA
[4] MIT, Francis Bitter Magnet Lab, Cambridge, MA 02139 USA
关键词
contrast agent; molecular imaging; sensor; temporal resolution; superparamagnetic nanoparticle;
D O I
10.1016/j.mri.2005.12.033
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Time-resolved MRI has had enormous impact in cognitive science and may become a significant tool in basic biological research with the application of new molecular imaging agents. In this paper, we examine the temporal characteristics of MRI contrast agents that could be used in dynamic studies. We consider "smart" T1 contrast agents, T2 agents based on reversible aggregation of superparamagnetic nanoparticles and sensors that produce changes in saturation transfer effects (chemical exchange saturation transfer, CEST). We discuss response properties of several agents with reference to available experimental data, and we develop a new theoretical model that predicts the response rates and relaxivity changes of aggregation-based sensors. We also perform calculations to define the extent to which constraints on temporal resolution are imposed by the imaging methods themselves. Our analysis confirms that some small T1 agents may be compatible with MRI temporal resolution on the order of 100 ins. Nanoparticle aggregation T2 sensors are applicable at much lower concentrations, but are likely to respond on a single second or slower timescale. CEST agents work at high concentrations and temporal resolutions of 1-10 s, limited by a requirement for long presaturation periods in the MRI pulse sequence. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:449 / 462
页数:14
相关论文
共 57 条
[41]  
Smoluchowski M. v., 1918, Phys. Chem. Streochiom. Verwandtschatsl, V92U, P129, DOI 10.1515/zpch-1918-9209
[42]   In vivo oxygen detection using exogenous hemoglobin as a contrast agent in magnetic resonance microscopy [J].
Sun, PZ ;
Schoening, ZB ;
Jasanoff, A .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (04) :609-614
[43]  
TOTH E, 2001, CHEM CONTRAST AGENTS
[44]   Solute and macromolecule diffusion in cellular aqueous compartments [J].
Verkman, AS .
TRENDS IN BIOCHEMICAL SCIENCES, 2002, 27 (01) :27-33
[45]  
Vicsek T, 1992, FRACTAL GROWTH PHENO
[46]   Superparamagnetic iron oxide contrast agents: physicochemical characteristics and applications in MR imaging [J].
Wang, YXJ ;
Hussain, SM ;
Krestin, GP .
EUROPEAN RADIOLOGY, 2001, 11 (11) :2319-2331
[47]   A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST) [J].
Ward, KM ;
Aletras, AH ;
Balaban, RS .
JOURNAL OF MAGNETIC RESONANCE, 2000, 143 (01) :79-87
[48]   In vivo magnetic resonance imaging of transgene expression [J].
Weissleder R. ;
Moore A. ;
Mahmood U. ;
Bhorade R. ;
Benveniste H. ;
Chiocca E.A. ;
Basilion J.P. .
Nature Medicine, 2000, 6 (3) :351-354
[49]   Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI [J].
Woessner, DE ;
Zhang, SR ;
Merritt, ME ;
Sherry, AD .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) :790-799
[50]   A paramagnetic CEST agent for imaging glucose by MRI [J].
Zhang, SR ;
Trokowski, R ;
Sherry, AD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (50) :15288-15289