An innovative phantom for quantitative and qualitative investigation of advanced x-ray imaging technologies

被引:26
作者
Chiarot, CB [1 ]
Siewerdsen, JH
Haycocks, T
Moseley, DJ
Jaffray, DA
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Ontario Canc Inst, Princess Margaret Hosp, Toronto, ON M5G 2M9, Canada
[3] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[4] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
关键词
D O I
10.1088/0031-9155/50/21/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Development, characterization, and quality assurance of advanced x-ray imaging technologies require phantoms that are quantitative and well suited to such modalities. This note reports on the design, construction, and use of an innovative phantom developed for advanced imaging technologies (e.g., multi-detector CT and the numerous applications of flat-panel detectors in dual-energy imaging, tomosynthesis, and cone-beam CT) in diagnostic and image-guided procedures. The design addresses shortcomings of existing phantoms by incorporating criteria satisfied by no other single phantom: (1) inserts are fully 3D-spherically symmetric rather than cylindrical; (2) modules are quantitative, presenting objects of known size and contrast for quality assurance and image quality investigation; (3) features are incorporated in ideal and semi-realistic (anthropomorphic) contexts; and (4) the phantom allows devices to be inserted and manipulated in an accessible module (right lung). The phantom consists of five primary modules: (1) head, featuring contrast-detail spheres approximate to brain lesions; (2) left lung, featuring contrast-detail spheres approximate to lung modules; (3) right lung, an accessible hull in which devices may be placed and manipulated; (4) liver, featuring conrast-detail spheres approximate to metastases; and (5) abdomen/pelvis, featuring simulated kidneys, colon, rectum, bladder, and prostate. The phantom represents a two-fold evolution in design philosophy-from 2D (cylindrically symmetric) to fully 3D, and from exclusively qualitative or quantitative to a design accommodating quantitative study within an anatomical context. It has proven a valuable tool in investigations throughout our institution, including low-dose CT, dual-energy radiography, and cone-beam CT for image-guided radiation therapy and surgery.
引用
收藏
页码:N287 / N297
页数:11
相关论文
共 7 条
  • [1] A multimodality vascular imaging phantom with fiducial markers visible in DSA, CTA, MRA, and ultrasound
    Cloutier, G
    Soulez, G
    Qanadli, SD
    Teppaz, P
    Allard, L
    Qin, Z
    Cloutier, F
    Durand, LG
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1424 - 1433
  • [2] A SLICE GEOMETRY PHANTOM FOR CROSS-SECTIONAL TOMOGRAPHIC IMAGERS
    COFFEY, CW
    TAYLOR, R
    UMSTEAD, G
    [J]. MEDICAL PHYSICS, 1989, 16 (02) : 273 - 278
  • [3] COFFEY CW, 1993, STEREOT FUNCT NEUROS, V61, P130, DOI 10.1159/000100667
  • [4] Tissue mimicking materials for a multi-imaging modality prostate phantom
    D'Souza, WD
    Madsen, EL
    Unal, O
    Vigen, KK
    Frank, GR
    Thomadsen, BR
    [J]. MEDICAL PHYSICS, 2001, 28 (04) : 688 - 700
  • [5] Use of a micro-ionization chamber and an anthropomorphic head phantom in a quality assurance program for stereotactic radiosurgery
    Duggan, DM
    Coffey, CW
    [J]. MEDICAL PHYSICS, 1996, 23 (04) : 513 - 516
  • [6] *INT COMM RAD UN M, 1989, 44 ICRU INT COMM RAD
  • [7] Multi-modality tissue-mimicking phantom for thermal therapy
    McDonald, M
    Lochhead, S
    Chopra, R
    Bronskill, MJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13) : 2767 - 2778