Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines

被引:145
作者
Sarzier, JS [1 ]
Evans, AJ [1 ]
Cahill, DW [1 ]
机构
[1] Univ S Florida, Dept Neurosurg, Div Intervent Neuroradiol, Tampa, FL 33606 USA
关键词
pedicle screw; polymethylmethacrylate; vertebroplasty;
D O I
10.3171/spi.2002.96.3.0309
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The authors conducted a biomechanical study to evaluate pedicle screw pullout strength in osteoporotic cadaveric spines. Nonaugmented hemivertebrae were compared with pressurized polymethylmethacrylate (PMMA)augmented hemivertebrae. Methods. Six formalin-fixed cadaveric thoracolumbar spines at least two standard deviations below the mean bone mineral density (BMD) for age were obtained. Radiographic and BMD studies were correlated to grades I, II, and III osteoporosis according to the Jekei scale. Each of the 21 vertebrae underwent fluoroscopic placement of 6-mm transpedicular screws with each hemivertebra serving as the control for the contralateral PMMA-augmented hemivertebra. Pedicle screws were then evaluated for biomechanical axial pullout resistance. Augmented hemivertebrae axial pullout forces were increased (p = 0.0005). The mean increase in pullout force was 181% for Grade I, 206% for Grade II, and 213% for Grade III osteoporotic spines. Augmented Grade I osteoporotic spines demonstrated axial pullout forces near those levels reported in the literature for nonosteoporotic specimens. Augmented Grade It osteoporotic specimens demonstrated increases to levels found in nonaugmented vertebrae with low-normal BMD. Augmented Grade III osteoporotic specimens had increases to levels equal to those found in nonaugmented Grade I vertebrae. Conclusions, Augmentation of osteoporotic vertebrae in PMMA-assisted vertebroplasty can significantly increase pedicle screw pullout forces to levels exceeding the strength of cortical bone. The maximum attainable force appears to be twice the pullout force of the nonaugmented pedicle screw for each osteoporotic grade.
引用
收藏
页码:309 / 312
页数:4
相关论文
共 25 条
[1]   BIOMECHANICAL ANALYSIS OF PEDICLE SCREW INSTRUMENTATION SYSTEMS IN A CORPECTOMY MODEL [J].
ASHMAN, RB ;
GALPIN, RD ;
CORIN, JD ;
JOHNSTON, CE .
SPINE, 1989, 14 (12) :1398-1405
[2]   THE EFFECTS OF PEDICLE SCREW FIT - AN IN-VITRO STUDY [J].
BRANTLEY, AGU ;
MAYFIELD, JK ;
KOENEMAN, JB ;
CLARK, KR .
SPINE, 1994, 19 (15) :1752-1758
[3]   INFLUENCE OF BONE-MINERAL DENSITY ON THE FIXATION OF THORACOLUMBAR IMPLANTS - A COMPARATIVE-STUDY OF TRANSPEDICULAR SCREWS, LAMINAR HOOKS, AND SPINOUS PROCESS WIRES [J].
COE, JD ;
WARDEN, KE ;
HERZIG, MA ;
MCAFEE, PC .
SPINE, 1990, 15 (09) :902-907
[4]   THE FIXATUER-INTERNE AS A VERSATILE IMPLANT FOR SPINE SURGERY [J].
DICK, W .
SPINE, 1987, 12 (09) :882-900
[5]   EFFECTS OF BONE-MINERAL DENSITY ON PEDICLE SCREW FIXATION [J].
HALVORSON, TL ;
KELLEY, LA ;
THOMAS, KA ;
WHITECLOUD, TS ;
COOK, SD .
SPINE, 1994, 19 (21) :2415-2420
[6]   COTREL DUBOUSSET PEDICLE SCREW SYSTEM FOR VARIOUS SPINAL-DISORDERS - MERITS AND PROBLEMS [J].
HIRABAYASHI, S ;
KUMANO, K ;
KUROKI, T .
SPINE, 1991, 16 (11) :1298-1304
[7]  
ITAMI Y, 1964, J JPN ORTHOP ASSOC, V38, P487
[8]  
Jensen ME, 1997, AM J NEURORADIOL, V18, P1897
[9]   ROY-CAMILLE PLATES IN UNSTABLE SPINAL CONDITIONS - A PRELIMINARY-REPORT [J].
KINNARD, P ;
GHIBELY, A ;
GORDON, D ;
TRIAS, A ;
BASORA, J .
SPINE, 1986, 11 (02) :131-135
[10]  
KOSTUIK JP, 1986, CLIN ORTHOP RELAT R, P219