Amplicon DNA melting analysis for mutation scanning and genotyping: Cross-platform comparison of instruments and dyes

被引:222
作者
Herrmann, MG
Durtschi, JD
Bromley, LK
Wittwer, CT
Voelkerding, KV
机构
[1] ARUP Labs, Inst Clin & Expt Pathol, Salt Lake City, UT 84108 USA
[2] Univ Utah, Sch Med, Dept Pathol, Salt Lake City, UT USA
关键词
D O I
10.1373/clinchem.2005.063438
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: DNA melting analysis for genotyping and mutation scanning of PCR products by use of high-resolution instruments with special "saturation" dyes has recently been reported. The comparative performance of other instruments and dyes has not been evaluated. Methods: A 110-bp fragment of the beta-globin gene including the sickle cell anemia locus (A17T) was amplified by PCR in the presence of either the saturating DNA dye, LCGreen Plus, or SYBR Green I. Amplicons of 3 different genotypes (wild-type, heterozygous, and homozygous mutants) were melted on 9 different instruments (ABI 7000 and 7900HT, Bio-Rad iCycler, Cepheid SmartCycler, Corbett Rotor-Gene 3000, Idaho Technology HR-1 and LightScanner, and the Roche LightCycler 1.2 and LightCycler 2.0) at a. rate of 0.1 degrees C/s or as recommended by the manufacturer. The ability of each instrument/dye combination to genotype by melting temperature (T-m) and to scan for heterozygotes by curve shape was evaluated. Results: Resolution varied greatly among instruments with a 15-fold difference in T-m SD (0.018 to 0.274 degrees C) and a 19-fold (LCGreen Plus) or 33-fold (SYBR Green 1) difference in the signal-to-noise ratio. These factors limit the ability of most instruments to accurately genotype single-nucleotide polymorphisms by amplicon melting. Plate instruments (96-well) showed the greatest variance with spatial differences across the plates. Either SYBR Green I or LCGreen Plus could be used for genotyping by T-m, but only LCGreen Plus was useful for heterozygote scanning. However, LCGreen Plus could not be used on instruments with an argon laser because of spectral mismatch. All instruments compatible with LCGreen Plus were. able to detect heterozygotes by altered melting curve shape. However, instruments specifically designed for high-resolution melting displayed the least variation, suggesting better scanning sensitivity and specificity. Conclusion: Different instruments and dyes vary widely in their ability to genotype homozygous variants and scan for heterozygotes by whole-amplicon melting analysis. (C) 2006 American Association for Clinical Chemistry.
引用
收藏
页码:494 / 503
页数:10
相关论文
共 31 条
[1]   Homogeneous multiplex genotyping of hemochromatosis mutations with fluorescent hybridization probes [J].
Bernard, PS ;
Ajioka, RS ;
Kushner, JP ;
Wittwer, CT .
AMERICAN JOURNAL OF PATHOLOGY, 1998, 153 (04) :1055-1061
[2]  
BOX EP, 1978, STAT EXPT INTRO DESI, P653
[3]   Real-time PCR assays targeting a unique chromosomal sequence of Yersinia pestis [J].
Chase, CJ ;
Ulrich, MP ;
Wasieloski, LP ;
Kondig, JP ;
Garrison, J ;
Lindler, LE ;
Kulesh, DA .
CLINICAL CHEMISTRY, 2005, 51 (10) :1778-1785
[4]   A comparison of high-resolution melting analysis with denaturing high-performance liquid chromatography for mutation scanning - Cystic fibrosis transmembrane conductance regulator gene as a model [J].
Chou, LS ;
Lyon, E ;
Wittwer, CT .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2005, 124 (03) :330-338
[5]   Fluorescein-labeled oligonucleotides for real-time PCR: Using the inherent quenching of deoxyguanosine nucleotides [J].
Crockett, AO ;
Wittwer, CT .
ANALYTICAL BIOCHEMISTRY, 2001, 290 (01) :89-97
[6]   Demonstration of preferential binding of SYBR Green I to specific DNA fragments in real-time multiplex PCR [J].
Giglio, S ;
Monis, PT ;
Saint, CP .
NUCLEIC ACIDS RESEARCH, 2003, 31 (22) :e136
[7]   Distinguishing different DNA heterozygotes by high-resolution melting [J].
Graham, R ;
Liew, M ;
Meadows, C ;
Lyon, E ;
Wittwer, CT .
CLINICAL CHEMISTRY, 2005, 51 (07) :1295-1298
[8]   Amplicon melting analysis with labeled primers: A closed-tube method for differentiating homozygotes and heterozygotes [J].
Gundry, CN ;
Vandersteen, JG ;
Reed, GH ;
Pryor, RJ ;
Chen, J ;
Wittwer, CT .
CLINICAL CHEMISTRY, 2003, 49 (03) :396-406
[9]   Single-tube genotyping of MBL-2 polymorphisms using melting temperature analysis [J].
Hladnik, U ;
Braida, L ;
Boniotto, M ;
Pirulli, D ;
Gerin, F ;
Amoroso, A ;
Crovella, S .
CLINICAL AND EXPERIMENTAL MEDICINE, 2002, 2 (02) :105-108
[10]  
Kleinle S., 2002, RAPID CYCLE REAL TIM, P47