Potentiometric oxygen sensor based on mixed potential of cobalt wire electrode

被引:17
作者
Meruva, RK [1 ]
Meyerhoff, ME [1 ]
机构
[1] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
关键词
blood-gas monitoring; sensors; mixed potential; potentiometry;
D O I
10.1016/S0003-2670(96)00570-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and simple potentiometric oxygen sensor suitable for the measurement of partial pressure of oxygen (P-O2) in flowing blood is described. The sensor is based on measuring a steady-state mixed potential that originates at the surface of a cobalt wire electrode. This mixed or corrosion potential arises from the slow oxidation of cobalt and simultaneous reduction of oxygen at the electrode surface, and changes as a function of sample P-O2 levels. The probe is fabricated with an outer gas permeable silicone rubber tubing (1.06 mm o.d.), which contains an internal buffer solution (25.0 mM potassium hydrogen phthalate, pH 4.0, containing 1.0 mM KCl), a cobalt wire (0.1 mm o.d.) as the working electrode and an Ag/AgCl wire as the reference electrode. The sensor characteristics (slope, detection limits, linear range, drift rates, etc.) along with the response mechanism based on mixed potential are discussed in detail. In vitro evaluation of catheter forms of the sensors performed in a blood loop indicate that the proposed sensor design can closely follow P-O2 changes induced in blood during 2-3 h of continuous monitoring.
引用
收藏
页码:187 / 194
页数:8
相关论文
共 13 条
[1]  
[Anonymous], 1962, J. Electroanal. Chem
[2]  
CLARK LC, 1956, T AM SOC ART INT ORG, V2, P41
[3]   MIXED-POTENTIAL MECHANISM FOR POTENTIOMETRIC RESPONSE OF SODIUM TUNGSTEN BRONZE ELECTRODE TO DISSOLVED-OXYGEN AND IN CHELOMETRIC TITRATIONS [J].
HAHN, PB ;
JOHNSON, DC ;
WECHTER, MA ;
VOIGT, AF .
ANALYTICAL CHEMISTRY, 1974, 46 (04) :553-558
[4]   SELECTIVITY CHARACTERISTICS OF POTENTIOMETRIC CARBON-DIOXIDE SENSORS WITH VARIOUS GAS MEMBRANE MATERIALS [J].
KOBOS, RK ;
PARKS, SJ ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1982, 54 (12) :1976-1980
[5]   Mixed potential response mechanism of cobalt electrodes toward inorganic phosphate [J].
Meruva, RK ;
Meyerhoff, ME .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2022-2026
[6]   POTENTIOMETRIC OXYGEN SENSING WITH COPPER-FILMS - RESPONSE MECHANISM AND ANALYTICAL IMPLICATIONS [J].
MERUVA, RK ;
MEYERHOFF, ME .
ELECTROANALYSIS, 1995, 7 (11) :1020-1026
[7]  
ROSS JW, 1973, PURE APPL CHEM, V36, P473
[8]  
SIEBERT E, 1986, ION SELECTIVE ELECT, V8, P133
[9]   SIMPLIFIED DUAL-LUMEN CATHETER DESIGN FOR SIMULTANEOUS POTENTIOMETRIC MONITORING OF CARBON-DIOXIDE AND PH [J].
TELTINGDIAZ, M ;
COLLISON, ME ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :576-583
[10]  
Vetter K.J., 1967, ELECTROCHEMICAL KINE