Orientation teeth in non-mechanical laser corneal trephination for penetrating keratoplasty:: 2.94 μm Er:YAG v 193 nm ArF excimer laser

被引:40
作者
Behrens, A [1 ]
Seitz, B [1 ]
Küchle, M [1 ]
Langenbucher, A [1 ]
Kus, NM [1 ]
Rummelt, C [1 ]
Naumann, GOH [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Ophthalmol, D-91054 Erlangen, Germany
关键词
D O I
10.1136/bjo.83.9.1008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims-"Orientation teeth" at the donor trephination margin and correspondent "notches" at the host margin facilitate graft orientation and avoid "horizontal torsion" induced by asymmetric suture placement. in this study the quality and reproducibility of these structures created by non-mechanical laser corneal trephination were compared using two laser emissions. Methods-The procedure was performed in 20 enucleated pigs" eyes using open metal masks with eight "orientation teeth/ notches" (0.3 x 0.15 mm, base x height), an automated globe rotation device, and either a 193 nm ArF excimer laser or a Q switched 2.94 pm Er:YAG laser. "Teeth/notches'" were analysed by planimetry and scanning electron microscopy (SEM). Results-Mean size was 0.30 (0.027) x 0.16 (0.017) mm for "teeth" and 0.30 (0.035) x 0.15 (0.021) mm for "notches" (excimer), and 0.31 (0.022) x 0.16 (0.015) mar and 0.30 (0.031) x 0.14 (0.021) ram respectively (Er:YAG). Overall, variability of notches was higher than that of teeth. Ey SEM, comparable cue regularity and sustained ablation profile were observed with both lasers. However, the corneal surface at the cut edge appeared slightly elevated (less than or equal to 35 pm) in the Er:YAG group. Conclusion-Orientation teeth/notches resembling those obtained with the excimer laser can be created using the Q switched Er:YAG laser, with potential advantages of lower costs, convenient equipment size, and solid stale safety.
引用
收藏
页码:1008 / 1012
页数:5
相关论文
共 28 条
[21]   Experimental 193-nm excimer laser trephination with divergent cut angles in penetrating keratoplasty [J].
Seitz, B ;
Behrens, A ;
Langenbucher, A ;
Kus, MM ;
Naumann, GOH .
CORNEA, 1998, 17 (04) :410-416
[22]  
Seitz B, 1998, OPHTHALMIC SURG LAS, V29, P33
[23]   Nonmechanical corneal trephination with the excimer laser improves outcome after penetrating keratoplasty [J].
Seitz, B ;
Langenbucher, A ;
Kus, MM ;
Küchle, M ;
Naumann, GOH .
OPHTHALMOLOGY, 1999, 106 (06) :1156-1164
[24]  
SEITZ B, 1994, INVEST OPHTH VIS SCI, V35, P1879
[25]  
SEITZ B, 1994, GER J OPHTHALMOL, V3, P310
[26]  
SEITZ B, 1997, OPHTHALMIC RES S1, V29, P82
[27]  
TROUTMAN RC, 1979, OPHTHALMIC SURG LAS, V10, P21
[28]   OVAL HOST WOUNDS AND POSTKERATOPLASTY ASTIGMATISM [J].
VILLACRIZ, E ;
RIFE, L ;
SMITH, RE .