The pathology of total joint arthroplasty - II. Mechanisms of implant failure

被引:237
作者
Bauer, TW
Schils, J
机构
[1] Cleveland Clin Fdn, Dept Pathol, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Orthopaed Surg, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Diagnost Radiol, Cleveland, OH 44195 USA
关键词
arthroplasty; osteolysis; implant loosening; wear; particles;
D O I
10.1007/s002560050552
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although the clinical results of total joint arthroplasty are usually excellent, some implants develop loosening and require revision. Implants usually fail by a combination of mechanisms, but different basic designs tend to show differ ent dominant mechanisms of failure. Infection causes failure of about 1-5% of cases of primary arthroplasty. Clues to the presence of infection include clinical signs, a periosteal reaction, a positive culture of aspirated joint fluid, and acute inflammation identified in tissue around the implant. There are several different mechanisms and modes of implant wear, and perhaps the most important cause of aseptic loosening is an inflammatory reaction to particles of wear debris. Abrasive, adhesive, and fatigue wear of polyethylene, metal and bone cement produces debris particles that induce bone resorption and implant loosening. Particles can cause linear, geographic, or erosive patterns of bone resorption (osteolysis), the distributions of which are influenced by the implant design. Micromotion of implants that did not achieve adequate initial fixation is another important mechanism of loosening. Fatigue failure at the bone/cement and bone/implant interface may cause aseptic loosening, and may be especially important for implants with relatively smooth surfaces. Stress shielding can influence local bone density, but is rarely an isolated cause of implant loosening. Elevated hydrodynamic pressure has been associated with bone resorption in the absence of implants, and may also play a role in implant loosening.
引用
收藏
页码:483 / 497
页数:15
相关论文
共 65 条
[11]  
Charnley J, 1968, J Bone Joint Surg Br, V50, P822
[12]  
Cooper R A, 1992, J Arthroplasty, V7, P285, DOI 10.1016/0883-5403(92)90050-Z
[13]  
DEVANE PA, 1995, CLIN ORTHOP RELAT R, V319, P317
[14]   A QUANTITATIVE-EVALUATION OF PERIPROSTHETIC BONE-REMODELING AFTER CEMENTLESS TOTAL HIP-ARTHROPLASTY [J].
ENGH, CA ;
MCGOVERN, TF ;
BOBYN, JD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1009-1020
[15]   CURRENT CONCEPTS REVIEW INFECTION AFTER TOTAL HIP-ARTHROPLASTY PAST, PRESENT, AND FUTURE [J].
GARVIN, KL ;
HANSSEN, AD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (10) :1576-1588
[16]  
Goodman S B, 1987, J Arthroplasty, V2, P219, DOI 10.1016/S0883-5403(87)80041-4
[17]   BACTERIAL ADHERENCE TO BIOMATERIALS AND TISSUE - THE SIGNIFICANCE OF ITS ROLE IN CLINICAL SEPSIS [J].
GRISTINA, AG ;
COSTERTON, JW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (02) :264-273
[18]   Evaluation and treatment of infection at the site of a total hip of knee arthroplasty [J].
Hanssen, AD ;
Rand, JA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (06) :910-922
[19]  
HASHIMOTO Y, 1995, T ORTHOP RES SOC, V20, P116
[20]  
Hirakawa K, 1996, J BIOMED MATER RES, V31, P257, DOI 10.1002/(SICI)1097-4636(199606)31:2<257::AID-JBM13>3.0.CO