The chemometric resolution and quantification of overlapped peaks form comprehensive two-dimensional liquid chromatography

被引:41
作者
Fraga, CG [1 ]
Corley, CA [1 ]
机构
[1] USAF Acad, Dept Chem, Colorado Springs, CO 80840 USA
关键词
liquid chromatography; two-dimensional; complex mixtures; GRAM; PARAFAC; three-way data; trilinear;
D O I
10.1016/j.chroma.2005.03.118
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The chemometric resolution and quantification of overlapped peaks from comprehensive two-dimensional (2D) liquid chromatography (LC x LC) data are demonstrated. The LC x LC data is produced from an in-house LC x LC analyzer that couples an anion-exchange column via a multi-port valve with a reversed-phase column connected to a UV absorbance detector. Three test mixtures, each containing a target analyte, are subjected to partial LC x LC separations to simulate likely cases of signal overlap. The resulting unresolved target-analyte signals are then analyzed by the standard-addition method and two chemometric methods. The LC x LC analyses of a test mixture and its corresponding standard-addition mixture results in two data matrices, one for each mixture. The stacking of these two data matrices produces a data structure that can then be analyzed by trilinear chemometric methods. One method, the generalized rank annihilation method (GRAM), uses a non-iterative eigenvalue-based approach to mathematically resolve overlapped trilinear signals. The other method, parallel factor analysis (PARAFAC), uses an iterative approach to resolve trilinear signals by the optimization of initial estimates using alternating least squares and signal constraints. In this paper, GRAM followed by PARAFAC analysis is shown to produce better qualitative and quantitative results than using each method separately. For instance, for all three test mixtures, the GRAM-PARAFAC approach improved quantitative accuracy by at least a factor of 4 and quantitative precision by more than 2 when compared to GRAM alone. This paper also introduces a new means of correcting run-to-run retention time shifts in comprehensive 2D chromatographic data. Published by Elsevier B.V.
引用
收藏
页码:40 / 49
页数:10
相关论文
共 52 条
[1]   The N-way Toolbox for MATLAB [J].
Andersson, CA ;
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 52 (01) :1-4
[2]   A new efficient method for determining the number of components in PARAFAC models [J].
Bro, R ;
Kiers, HAL .
JOURNAL OF CHEMOMETRICS, 2003, 17 (05) :274-286
[3]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[4]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[5]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[6]   Separation and identification of compounds in Rhizoma chuanxiong by comprehensive two-dimensional liquid chromatography coupled to mass spectrometry [J].
Chen, XG ;
Kong, L ;
Su, XY ;
Fu, HJ ;
Ni, JY ;
Zhao, RH ;
Zou, HF .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1040 (02) :169-178
[7]   Quantification from highly drifted and overlapped chromatographic peaks using second-order calibration methods [J].
Comas, E ;
Gimeno, RA ;
Ferré, J ;
Marcé, RM ;
Borrull, F ;
Rius, FX .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1035 (02) :195-202
[8]   Comprehensive two-dimensional normal-phase (adsorption) - Reversed-phase liquid chromatography [J].
Dugo, P ;
Favoino, O ;
Luppino, R ;
Dugo, G ;
Mondello, L .
ANALYTICAL CHEMISTRY, 2004, 76 (09) :2525-2530
[9]   Critical evaluation of two F-tests for selecting the number of factors in abstract factor analysis [J].
Faber, K ;
Kowalski, BR .
ANALYTICA CHIMICA ACTA, 1997, 337 (01) :57-71
[10]   GENERALIZED RANK ANNIHILATION METHOD .1. DERIVATION OF EIGENVALUE PROBLEMS [J].
FABER, NM ;
BUYDENS, LMC ;
KATEMAN, G .
JOURNAL OF CHEMOMETRICS, 1994, 8 (02) :147-154