Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices

被引:383
作者
Crow, Sheri [1 ]
John, Ranjit [2 ]
Boyle, Andrew [3 ]
Shumway, Sara [2 ]
Liao, Kenneth [2 ]
Colvin-Adams, Monica [3 ]
Toninato, Carol [2 ]
Missov, Emil [3 ]
Pritzker, Marc [3 ]
Martin, Cindy [3 ]
Garry, Daniel [3 ]
Thomas, William [4 ]
Joyce, Lyle [2 ]
机构
[1] Mayo Clin, Div Pediat Crit Care Med, Rochester, MN USA
[2] Univ Minnesota, Dept Med, Div Cardiothorac Surg, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Dept Med, Div Cardiol, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Dept Med, Div Biostat, Minneapolis, MN 55455 USA
关键词
FLOW; DISEASE; ANGIODYSPLASIA;
D O I
10.1016/j.jtcvs.2008.07.032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Pulsatile and nonpulsatile left ventricular assist devices are effective in managing congestive heart failure. Despite early evidence for clinical efficacy, the long-term impact of nonpulsatile flow on end-organ function remains to be determined. Our goal was to compare rates of gastrointestinal bleeding in nonpulsatile and pulsatile device recipients. Methods: In a retrospective review of 101 left ventricular assist device recipients (55 nonpulsatile, 46 pulsatile) from October 31, 2003, to June 1, 2007, at a single center, gastrointestinal bleeding was defined as guaiac-positive stool with hemoglobin drop requiring transfusion of at least 2 units of packed red blood cells. To assess bleeding risk outside the initial postoperative course, any patients with a device in place for 15 days or less was excluded. Results: Twelve nonpulsatile and 3 pulsatile left ventricular assist device recipients had gastrointestinal bleeding 16 days or longer after device implantation. The event rates were 63 events/100 patient-years for nonpulsatile devices and 6.8 events/100 patient-years for pulsatile devices (P = .0004). This difference persisted for bleeding occurring 31 days or longer after device implantation, with 46.5 events/100 patient-years for nonpulsatile devices versus 4.7 events/100 patient-years for pulsatile devices (P = .0028). Mortalities were similar between groups (15% nonpulsatile vs 17% pulsatile, P = .6965). Conclusion: Patients with nonpulsatile left ventricular assist devices appear to have a higher rate of gastrointestinal bleeding events than do pulsatile left ventricular assist device recipients. Further prospective evaluation is needed to determine potential etiologies and strategies for reducing gastrointestinal bleeding in this population.
引用
收藏
页码:208 / 215
页数:8
相关论文
共 19 条
  • [1] American Heart Association, HEART FAILURE
  • [2] THROMBOEMBOLIC AND BLEEDING COMPLICATIONS IN PATIENTS WITH MECHANICAL HEART-VALVE PROSTHESES
    CANNEGIETER, SC
    ROSENDAAL, FR
    BRIET, E
    [J]. CIRCULATION, 1994, 89 (02) : 635 - 641
  • [3] CESSATION OF RECURRENT BLEEDING FROM GASTROINTESTINAL ANGIODYSPLASIAS AFTER AORTIC-VALVE REPLACEMENT
    CAPPELL, MS
    LEBWOHL, O
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 105 (01) : 54 - 57
  • [4] Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients
    Feller, Erika D.
    Sorensen, Erik N.
    Haddad, Michel
    Pierson, Richard N., III
    Johnson, Frances L.
    Brown, James M.
    Griffith, Bartley P.
    [J]. ANNALS OF THORACIC SURGERY, 2007, 83 (03) : 1082 - 1088
  • [5] Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation
    Frazier, OH
    Rose, EA
    Oz, MC
    Dembitsky, W
    McCarthy, P
    Radovancevic, B
    Poirier, VL
    Dasse, KA
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (06) : 1186 - 1195
  • [6] First experiences with a novel magnetically suspended axial flow left ventricular assist device
    Hetzer, R
    Weng, YG
    Potapov, EV
    Pasic, M
    Drews, T
    Jurmann, M
    Hennig, E
    Müller, J
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (06) : 964 - 970
  • [7] HEYDE EC, 1958, NEW ENGL J MED, V259, P196
  • [8] Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device
    Letsou, GV
    Shah, N
    Gregoric, ID
    Myers, TJ
    Delgado, R
    Frazier, OH
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (01) : 105 - 109
  • [9] Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months
    Letsou, GV
    Myers, TJ
    Gregoric, ID
    Delgado, R
    Shah, N
    Robertson, K
    Radovancevic, B
    Frazier, OH
    [J]. ANNALS OF THORACIC SURGERY, 2003, 76 (04) : 1167 - 1170
  • [10] Hemorrhagic complications of anticoagulant treatment
    Levine, MN
    Raskob, G
    Beyth, RJ
    Kearon, C
    Schulman, S
    [J]. CHEST, 2004, 126 (03) : 287S - 310S