Advantages of using multiple-echo image combination and asymmetric triangular phase masking in magnetic resonance venography at 3 T

被引:19
作者
Brainovich, Valentina [1 ]
Sabatini, Umberto [2 ]
Hagberg, Gisela E. [1 ]
机构
[1] Fdn Santa Lucia, Neuroimaging Lab, IRCCS, I-00179 Rome, Italy
[2] Fdn Santa Lucia, Dept Radiol, IRCCS, I-00179 Rome, Italy
关键词
SWI; Venography; BOLD dephasing; Susceptibility effects; BLOOD-OXYGENATION; FUNCTIONAL MRI; HUMAN BRAIN; BOLD FMRI; 3.0; TESLA; SUSCEPTIBILITY; RESOLUTION; CONTRAST; SIGNAL; ACTIVATION;
D O I
10.1016/j.mri.2008.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The present work explores the possibility of localizing veins with magnetic resonance venography using susceptibility weighted imaging. It also seeks new approaches, directed by the spatial specificity of activated brain regions, that have sufficient precision for practical use in functional MRI studies. A 3D flow compensated Multiple gradient echo sequence, featuring optimized T2* weighting within a reasonable time of acquisition (11 min) and a small voxel size (0.5x0.5x1 mm(3)), was used to acquire MR images at 3 T. Post-processing consisted of homodyne filtering, linear phase scaling and magnitude masking prior to minimum intensity projection (m[P). The multiple echo approach provided a satisfactory (48 +/- 7%) increase in signal-to-noise ratio with respect to conventional methods. Specific features of the blood oxygenation level-dependent phase effect were simulated and used for designing and exploring different phase masking methods in relation to vessel morphology and MRI voxel geometry. As with simulations, the best results were obtained with an asymmetric triangular phase masking, featuring an improved venographic contrast without any increase in the full-width at half-maximum. The multiple echo approach provided satisfactory vessel localization capacity by using asymmetric triangular phase masking and a 4-mm-thick mIP. The venographic contrast obtained enabled the detection of vessels with diameter down to approximately 500 mu m, suggesting the applicability of the proposed method as an additional technique in fMRI Studies. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:23 / 37
页数:15
相关论文
共 38 条
[1]   Current-induced magnetic resonance phase imaging [J].
Bodurka, J ;
Jesmanowicz, A ;
Hyde, JS ;
Xu, H ;
Estkowski, L ;
Li, SJ .
JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) :265-271
[2]   Functional MRI with variable echo time acquisition [J].
Chen, NK ;
Egorova, S ;
Guttmann, CRG ;
Panych, LP .
NEUROIMAGE, 2003, 20 (04) :2062-2070
[3]   Predicting BOLD signal changes as a function of blood volume fraction and resolution [J].
Cheng, YCN ;
Haacke, EM .
NMR IN BIOMEDICINE, 2001, 14 (7-8) :468-477
[4]  
CHU SCK, 1990, MAGN RESON MED, V13, P239, DOI 10.1002/mrm.1910130207
[5]   Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head [J].
Collins, CM ;
Yang, B ;
Yang, QX ;
Smith, MB .
MAGNETIC RESONANCE IMAGING, 2002, 20 (05) :413-424
[6]   Theoretical and experimental investigation of the VASO contrast mechanism [J].
Donahue, Manus J. ;
Lu, Hanzhang ;
Jones, Craig K. ;
Edden, Richard A. E. ;
Pekar, James J. ;
van Zijl, Peter C. M. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) :1261-1273
[7]   EPI-BOLD fMRI of human motor cortex at 1.5 T and 3.0 T: Sensitivity dependence on echo time and acquisition bandwidth [J].
Fera, F ;
Yongbi, MN ;
van Gelderen, P ;
Frank, JA ;
Mattay, VS ;
Duyn, JH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (01) :19-26
[8]   Experimental determination of the BOLD field strength dependence in vessels and tissue [J].
Gati, JS ;
Menon, RS ;
Ugurbil, K ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :296-302
[9]   Susceptibility weighted imaging (SWI) [J].
Haacke, EM ;
Xu, YB ;
Cheng, YCN ;
Reichenbach, JR .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) :612-618
[10]   In vivo measurement of changes in venous blood-oxygenation with high resolution functional MRI at 0.95 Tesla by measuring changes in susceptibility and velocity [J].
Hoogenraad, FGC ;
Reichenbach, JR ;
Haacke, EM ;
Lai, S ;
Kuppusamy, K ;
Sprenger, M .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) :97-107