Determination of the nutraceutical, glucosamine hydrochloride, in raw materials, dosage forms and plasma using pre-column derivatization with ultraviolet HPLC

被引:69
作者
Liang, ZM [1 ]
Leslie, J [1 ]
Adebowale, A [1 ]
Ashraf, M [1 ]
Eddington, ND [1 ]
机构
[1] Univ Maryland, Sch Pharm, Dept Pharmaceut Sci, Pharmacokinet Biopharmaceut Lab, Baltimore, MD 21201 USA
关键词
glucosamine hydrochloride; nutraceutical; phenylisothiocyanate; arthritis;
D O I
10.1016/S0731-7085(99)00085-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective and specific high performance liquid chromatography method was developed to quantitate glucosamine hydrochloride in raw materials, dosage forms and plasma. Reverse phase chromatography using pre-column derivatization with phenylisothiocyanate, and ultraviolet detection (lambda = 254 nm) was used to quantify the eluate. The mobile phase consisted of MeOH/H2O/CH3COOH (10:89.6:0.04) and was pumped at a flow rate of 1.2 ml/min. The standard curves for glucosamine hydrochloride showed linearity (r greater than or equal to 0.99) over the selected concentration range from 6.65 to 16.63 mu g/ml for raw materials and dosage forms. The precision of the dosage form assay, expressed as the % relative standard deviation (R.S.D.), was < 5% at all concentrations. The intra-day and inter-day accuracy, as indicated by the relative error (R.E.), ranged from - 2.54 to 2.70% for glucosamine hydrochloride. For the plasma assay, beagle dog plasma tvas used to prepare standard curves in the concentration range of 1.25-20 mu g/ml. Precipitation of plasma proteins was accomplished with acetonitrile to separate interfering endogenous products from the compound of interest. The supernatant was derivatized using phenylisocyanate in phosphate buffer (pH = 8.3) and subsequently evaporated to dryness under a nitrogen stream at 42 degrees C. The residue was dissolved in 250 mu l mobile phase and injected onto the chromatographic system. The assay was linear in concentration ranges of 1.25-20 mu g/ml (r greater than or equal to 0.999). Intra- and inter-day precision was less than or equal to 5.23 and 5.65%, respectively and the intra- and inter-day accuracy, indicated by R.E., ranged from - 8.6 to 10.35%. The method was found to be specific and with excellent linearity, accuracy and precision and is well suited for the quantitation of glucosamine hydrochloride in raw materials, dosage forms, and pharmacokinetic studies. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:807 / 814
页数:8
相关论文
共 14 条
[1]   THERAPEUTIC TREATMENT OF CANINE OSTEO-ARTHRITIS WITH GLYCOSAMINOGLYCAN POLYSULFURIC ACID ESTER [J].
ALTMAN, RD ;
DEAN, DD ;
MUNIZ, OE ;
HOWELL, DS .
ARTHRITIS AND RHEUMATISM, 1989, 32 (10) :1300-1307
[2]   QUANTITATIVE-DETERMINATION OF PHENYL ISOTHIOCYANATE-DERIVATIZED AMINO-SUGARS AND AMINO SUGAR ALCOHOLS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ANUMULA, KR ;
TAYLOR, PB .
ANALYTICAL BIOCHEMISTRY, 1991, 197 (01) :113-120
[3]  
BINDLINGMEYER BA, 1984, J CHROMATOGR, V336, P93
[4]  
CONTE A, 1995, ARZNEIMITTEL-FORSCH, V45-2, P918
[5]   Amino acid and amino sugar determination by derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate followed by high-performance liquid chromatography and fluorescence detection [J].
Diaz, J ;
Lliberia, JL ;
Comellas, L ;
BrotoPuig, F .
JOURNAL OF CHROMATOGRAPHY A, 1996, 719 (01) :171-179
[6]  
GREILING HW, 1984, METHOD ENZYMAT AN, P60
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC QUANTITATION OF PHENYLTHIOCARBAMYL MURAMIC ACID AND GLUCOSAMINE FROM BACTERIAL-CELL WALLS [J].
HAGEN, SR .
JOURNAL OF CHROMATOGRAPHY, 1993, 632 (1-2) :63-68
[8]  
Hanson RR, 1996, EQUINE PRACT, V18, P18
[9]  
HUBER ML, 1994, COMP CONT EDUC PRACT, V16, P501
[10]  
McNair K, 1997, EQUINE PRACT, V19, P9