Techniques for high-quality ambient coarse particle mass measurements

被引:11
作者
Allen, GA
Oh, JAA
Koutrakis, P
Sioutas, C
机构
[1] Harvard Univ, Sch Publ Hlth, Boston, MA 02115 USA
[2] Univ So Calif, Dept Civil & Environm Engn, Los Angeles, CA 90089 USA
关键词
D O I
10.1080/10473289.1999.10463893
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Several recent studies have shown associations between ambient concentrations of particle mass (PM) and rates of morbidity and mortality in the general population. These studies have raised the issue of quality of coarse mass (CM, PM between 2.5 and 10 mu m) data used for these purposes. CM data may have precision three or more times worse than the associated PM2.5 or PM10 data, depending on the measurement method, PM2.5 to PM10 ratios, and CM concentrations. CM is measured either as the difference between collocated PM10 and PM2.5 samplers or more directly with a dichotomous (virtual impactor) sampler. CM precision for the difference method is degraded due to the increased errors inherent with using the difference between two independent measurements, as well as the high PM2.5 to PM10 ratios (and low CM concentrations) typical of the eastern United States. The dichotomous sampler (dichot) makes a more direct measurement of CM, but there is a potential for significant postexposure loss of particles from unoiled CM dichot filters, as well as uncertainties in the dichot's CM channel enrichment factor. Compared to the dichot, low-volume inertial impactor samplers such as the Harvard Impactor (HI) or PM2.5 Federal Reference Method (FRM) are simpler to operate and maintain, provide sharper cut points, and do not require oiled filters to prevent loss of CM from the filter during transport. With the recent interest in CM spatial and temporal variability with respect to PM health effects, we have developed modifications to the HI PM method to provide measurements of 24-hour PM with estimated CM precision of better than 5% CV and r(2) higher than 0.95, primarily by lowering field blank variability and increasing gravimetric analytical precision. These high-precision PM techniques are not limited to the HI sampler; they can also be applied to the PM2.5 FRM sampler. The measurement methods described here can be applied to future PM studies to avoid the potential problems with exposure assessment caused by CM measurements that have poor precision.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 25 条
[1]  
ALLEN GA, 1997, P A WMA EPA S MEAS T
[2]   Spatial variation in particulate concentrations within metropolitan Philadelphia [J].
Burton, RM ;
Suh, HH ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (02) :400-407
[3]  
CAMP DC, 1980, ENVIRON INT, V4, P83
[4]   AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES [J].
DOCKERY, DW ;
POPE, CA ;
XU, XP ;
SPENGLER, JD ;
WARE, JH ;
FAY, ME ;
FERRIS, BG ;
SPEIZER, FE .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) :1753-1759
[5]   STATISTICAL UNCERTAINTIES IN AEROSOL MASS CONCENTRATIONS MEASURED BY VIRTUAL IMPACTORS [J].
EVANS, JS ;
RYAN, PB .
AEROSOL SCIENCE AND TECHNOLOGY, 1983, 2 (04) :531-536
[6]  
Federal Registe, 1997, FED REG 0718, V62, P38855
[7]   AN INTERCOMPARISON OF THE INDOOR AIR SAMPLING IMPACTOR AND THE DICHOTOMOUS SAMPLER FOR A 10-MU-M CUT SIZE [J].
LIOY, PJ ;
WAINMAN, T ;
TURNER, W ;
MARPLE, VA .
JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1988, 38 (05) :668-670
[8]   UNCERTAINTIES IN IDENTIFYING RESPONSIBLE POLLUTANTS IN OBSERVATIONAL EPIDEMIOLOGY STUDIES [J].
LIPFERT, FW ;
WYZGA, RE .
INHALATION TOXICOLOGY, 1995, 7 (05) :671-689
[9]   Air pollution and mortality: The implications of uncertainties in regression modeling and exposure measurement [J].
Lipfert, FW ;
Wyzga, RE .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (04) :517-523
[10]   DEVELOPMENT OF HIGH-EFFICIENCY VIRTUAL IMPACTORS [J].
LOO, BW ;
CORK, CP .