Focused microwave phased array thermotherapy for primary breast cancer

被引:41
作者
Gardner, RA
Vargas, HI
Block, JB
Vogel, CL
Fenn, AJ
Kuehl, GV
Doval, M
机构
[1] Columbia Hosp, Ctr Breast Care, W Palm Beach, FL 33407 USA
[2] Harbor UCLA Med Ctr, Torrance, CA 90509 USA
[3] MIT, Lexington, MA USA
关键词
thermotherapy; hyperthermia; adaptive microwave phased array; breast cancer; thermal dose;
D O I
10.1245/aso.2002.9.4.326
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: A pilot safety study of focused microwave phased array thermotherapy in the treatment of primary breast carcinomas was conducted. Methods: Ten patients with breast carcinomas beneath the skin surface that ranged in maximal clinical size from 1 to 8 cm (mean, 4.3 cm) were treated with the breast compressed in the prone position. We planned to deliver a tumor thermal dose equivalent to 60 minutes at 43degreesC. Breast imaging and pathology data were used to assess efficacy. Results: For the 10 patients, the mean tumor equivalent thermal dose was 51.7 minutes, the mean peak tumor temperature was 44.9degreesC, and the mean treatment time was 34.7 minutes. Ultrasound imaging demonstrated a significant reduction in tumor size (mean, 41%) 5 to 18 days after thermotherapy in 6 (60%) of 10 patients. A significant tumor response on the basis of reduction in tumor size or significant tumor cell kill occurred in 8 (80%) of 10 patients. Conclusions: With sufficient skin cooling, delivery of focused microwave phased array thermotherapy is safe in treating breast carcinomas when used alone, and some potential efficacy was demonstrated at the tumor thermal doses administered. Increased tumor thermal dose efficacy studies in larger patient populations for improved breast conservation should be investigated.
引用
收藏
页码:326 / 332
页数:7
相关论文
共 37 条
[1]  
BASSEN H, 1978, CANC THERAPY HYPERTH, P15
[2]   Stereotactic core-needle biopsy of the breast: A report of the joint task force of the American College of Radiology, American College of Surgeons, and College of American Pathologists [J].
Bassett, L ;
Winchester, DP ;
Caplan, RB ;
Dershaw, DD ;
Dowlatshahi, K ;
Evans, WP ;
Fajardo, LL ;
Fitzgibbons, PL ;
Henson, DE ;
Hutter, RVP ;
Morrow, M ;
Paquelet, JR ;
Singletary, SE ;
Curry, J ;
WilcoxBuchalla, P ;
Zinninger, M .
CA-A CANCER JOURNAL FOR CLINICIANS, 1997, 47 (03) :171-+
[3]   DIELECTRIC-PROPERTIES OF FEMALE HUMAN BREAST-TISSUE MEASURED INVITRO AT 3.2 GHZ [J].
CAMPBELL, AM ;
LAND, DV .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :193-210
[4]  
CHAUDHARY SS, 1984, INDIAN J BIOCHEM BIO, V21, P76
[5]   DUAL-BEAM TEM APPLICATOR FOR DIRECT-CONTACT HEATING OF DIELECTRICALLY ENCAPSULATED MALIGNANT MOUSE TUMOR [J].
CHEUNG, AY ;
DAO, T ;
ROBINSON, JE .
RADIO SCIENCE, 1977, 12 (06) :81-85
[6]  
EBERLEIN TJ, 1990, ARCH SURG-CHICAGO, V125, P771
[7]   ADAPTIVE RADIOFREQUENCY HYPERTHERMIA-PHASED ARRAY SYSTEM FOR IMPROVED CANCER-THERAPY - PHANTOM TARGET MEASUREMENTS [J].
FENN, AJ ;
KING, GA .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1994, 10 (02) :189-208
[8]   An adaptive microwave phased array for targeted heating of deep tumours in intact breast: animal study results [J].
Fenn, AJ ;
Wolf, GL ;
Fogle, RM .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1999, 15 (01) :45-61
[9]   Experimental investigation of an adaptive feedback algorithm for hot spot reduction in radio-frequency phased-array hyperthermia [J].
Fenn, AJ ;
King, GA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (03) :273-280
[10]  
Fenn AJ, 1998, J ONCOLOGY MANAGEMEN, V7, P22