A pre-concentration procedure using cloud point extraction for the determination of uranium in natural water

被引:63
作者
Ferreira, HS
Bezerra, MD
Ferreira, SLC
机构
[1] Univ Fed Bahia, Inst Quim Nucleo Excelencia Quim Analit Bahia, BR-40170290 Salvador, BA, Brazil
[2] Univ Estadual Sudoeste Bahia, Dept Quim & Exatas, BR-45206190 Jequie, BA, Brazil
关键词
cloud point extraction; uranium determination; natural water; molecular absorption spectrometry;
D O I
10.1007/s00604-005-0475-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A pre-concentration procedure using cloud point extraction is presented for the determination of uranium in natural water using molecular absorption spectrometry. The ligand used was 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol (Br-PADAP) and the micellar phase was obtained using the non-ionic surfactant octylphenoxypoly-ethoxyethanol (Triton X-114) and centrifugation. Interferences were eliminated using a masking solution containing trans-1,2-cyclohexanediaminetetraacetic acid (CDTA), sodium fluoride and sulphosalicylic acid. The optimization step was performed using a two-level factorial design and a Doehlert matrix, involving the factors pH, centrifugation time and buffer concentration. The method allows the determination of uranium in water samples with a detection limit of 0.15 mu g L-1, a quantification limit of 0.50 mu g L-1 and a precision expressed as relative standard deviation of 1.8 and 2.3% for uranium concentrations of 5 and 10 mu g L-1, respectively (n = 8). The accuracy was confirmed by analysis of two certified samples of natural water. This method was applied to the determination of uranium in superficial water samples collected at a uranium mine in Brazil. For five samples analyzed, the concentration of uranium varied between 1.1 and 18.1 mu g L-1. Tests of addition/recovery were performed for all these samples, and the results varying between 98 and 105% also proved that this procedure is not affected by the matrix and can be applied satisfactorily to the determination of uranium in water samples.
引用
收藏
页码:163 / 167
页数:5
相关论文
共 37 条
[21]  
LIU ZF, 1991, ANALYST, V116, P95
[22]   Cloud point preconcentration and flame atomic absorption spectrometric determination of cobalt and nickel in water samples [J].
Manzoori, JL ;
Bavili-Tabrizi, A .
MICROCHIMICA ACTA, 2003, 141 (3-4) :201-207
[23]   Cloud point extraction for the deten-nination of cadmium and lead in biological samples by graphite furnace atomic absorption spectrometry [J].
Maranhao, TD ;
Borges, DLG ;
da Veiga, MAMS ;
Curtius, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (05) :667-672
[24]   Amberlite XAD-4 functionalized with succinic acid for the solid phase extractive preconcentration and separation of uranium(VI) [J].
Metilda, P ;
Sanghamitra, K ;
Gladis, JM ;
Naidu, GRK ;
Rao, TP .
TALANTA, 2005, 65 (01) :192-200
[25]  
Montaser A., 1992, INDUCTIVELY COUPLED
[26]   Cloud point formation based on mixed micelles in the presence of electrolytes for cobalt extraction and preconcentration [J].
Nascentes, CC ;
Arruda, MAZ .
TALANTA, 2003, 61 (06) :759-768
[27]   Depleted uranium: possible health effects and experimental issues [J].
Nuccetelli, C ;
Grandolfo, M ;
Risica, S .
MICROCHEMICAL JOURNAL, 2005, 79 (1-2) :331-335
[28]   Radiometric determination of uranium in natural waters after enrichment and separation by cation-exchange and liquid-liquid extraction [J].
Pashalidis, I ;
Tsertos, H .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 260 (03) :439-442
[29]   Trends in preconcentration procedures for metal determination using atomic spectrometry techniques [J].
Pereira, MD ;
Arruda, MAZ .
MICROCHIMICA ACTA, 2003, 141 (3-4) :115-131
[30]   Focussed microwave-assisted sample preparation: total phenol determination in petroleum refinery effluents by flow injection spectrophotometry [J].
Quaresma, MCB ;
Cassella, RJ ;
Carvalho, MFB ;
Santelli, RE .
MICROCHEMICAL JOURNAL, 2004, 78 (01) :35-40