Implanted cardiovascular polymers: Natural, synthetic and bio-inspired

被引:251
作者
Venkatraman, Subbu [1 ]
Boey, Freddy [1 ]
Lao, Luciana Lisa [1 ]
机构
[1] Nanyang Technol Univ, Sch Mat Sci & Engn, Singapore 639798, Singapore
关键词
Vascular graft; Endothelial cell seeding; Expanded poly(tetrafluoroethylene); Polyester; Poly(L-lactide); Biodegradable stent; Drug-eluting stent; Vessel patency; Artificial proteins; Collagen and elastin;
D O I
10.1016/j.progpolymsci.2008.07.001
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 [高分子化学与物理]; 080501 [材料物理与化学]; 081704 [应用化学];
摘要
This review details the use of polymeric biomaterials used in implantable cardiovascular devices. Specifically, the role of the polymer in two major types of device, the vascular graft and the cardiovascular stent, is examined critically. In these two devices, the device performance is critically dependent on the polymer; the material requirements are detailed, and the shortcomings of currently used polymers highlighted with a view to furthering the development of new materials. In each category, synthetic polymers, polymers of natural origin, and polymers that mimic proteins but are synthesized, have all been evaluated with varying degrees of success. We find that the totally artificial graft is still the preferred option when autologous vessels are not available; the development of a completely tissue-engineered graft awaits improvements in scaffold materials as well as in tissue reactor engineering. In the field of stents, current consensus is driving the substitution of a biodegradable, polymeric stent for the biostable metallic one. Although various biodegradable polymers have been evaluated, the hydrolytically degradable polyesters continue to be the polymer of choice. New developments in biodegradable polymers are highlighted, and their performance in terms of biocompatibility, and controlled degradability are presented. The outlook for the next decade appears hopeful, with improvements in cell-seeding and cell growth techniques expected to enhance the performance of both types of implanted device. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:853 / 874
页数:22
相关论文
共 145 条
[1]
EFFECT OF COMPLIANCE MISMATCH ON VASCULAR GRAFT PATENCY [J].
ABBOTT, WM ;
MEGERMAN, J ;
HASSON, JE ;
LITALIEN, G ;
WARNOCK, DF .
JOURNAL OF VASCULAR SURGERY, 1987, 5 (02) :376-382
[2]
THE EFFECT OF CARBON COATING AND POROSITY ON EARLY PATENCY OF EXPANDED POLYTETRAFLUOROETHYLENE GRAFTS - AN EXPERIMENTAL-STUDY [J].
AKERS, DL ;
DU, YH ;
KEMPCZINSKI, RF .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (01) :10-15
[3]
In vitro study of release mechanisms of paclitaxel and rapamycin from drug-incorporated biodegradable stent matrices [J].
Alexis, F ;
Venkatraman, SS ;
Rath, SK ;
Boey, F .
JOURNAL OF CONTROLLED RELEASE, 2004, 98 (01) :67-74
[4]
Intraocular lens implants - Have come a long way, but the advances are not yet available to all [J].
Allan, B .
BRITISH MEDICAL JOURNAL, 2000, 320 (7227) :73-74
[5]
Prospective randomized study of carbon-impregnated polytetrafluoroethylene grafts for below-knee popliteal and distal bypass: Results at 2 years [J].
Bacourt, F .
ANNALS OF VASCULAR SURGERY, 1997, 11 (06) :596-603
[6]
Bär FW, 2000, J BIOMED MATER RES, V52, P193, DOI 10.1002/1097-4636(200010)52:1<193::AID-JBM25>3.0.CO
[7]
2-7
[8]
BECK A, 1990, RADIOLOGE, V30, P347
[9]
Eligard®:: Pharmacokinetics, effect on testosterone and PSA levels and tolerability [J].
Berges, R .
EUROPEAN UROLOGY SUPPLEMENTS, 2005, 4 (05) :20-25
[10]
Viscoelastic testing methodologies for tissue engineered blood vessels [J].
Berglund, JD ;
Nerem, RM ;
Sambanis, A .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (07) :1176-1184