Can endotracheal bioimpedance cardiography assess hemodynamic response to passive leg raising following cardiac surgery?

被引:18
作者
Fellahi, Jean-Luc [1 ,2 ]
Fischer, Marc-Olivier [1 ]
Dalbera, Audrey [1 ]
Massetti, Massimo [2 ,3 ]
Gerard, Jean-Louis [1 ,2 ]
Hanouz, Jean-Luc [1 ,2 ]
机构
[1] CHU Caen, Dept Anesthesiol & Crit Care Med, F-14000 Caen, France
[2] Univ Caen, Fac Med, F-14000 Caen, France
[3] CHU Caen, Dept Cardiothorac Surg, F-14000 Caen, France
来源
ANNALS OF INTENSIVE CARE | 2012年 / 2卷
关键词
Cardiac surgery; Cardiac monitoring; Bioimpedance cardiography; Passive leg raising; Fluid responsiveness;
D O I
10.1186/2110-5820-2-26
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The utility of endotracheal bioimpedance cardiography (ECOM) has been scarcely reported. We tested the hypothesis that it could be an alternative to pulse contour analysis for cardiac index measurement and prediction in fluid responsiveness. Methods: Twenty-five consecutive adult patients admitted to the intensive care unit following conventional cardiac surgery were prospectively included and investigated at baseline, during passive leg raising, and after fluid challenge. Comparative cardiac index data points were collected from pulse contour analysis (CIPC) and ECOM (CIECOM). Correlations were determined by linear regression. Bland-Altman analysis was used to compare the bias, precision, and limits of agreement. Percentage error was calculated. Changes in CIPC (Delta CIPC) and CIECOM (Delta CIECOM) during passive leg raising were collected to assess their discrimination in predicting fluid responsiveness. Results: A significant relationship was found between CIPC and CIECOM (r = 0.45; P< 0.001). Bias, precision, and limits of agreement were 0.44 L. min(-1). m(-2) (95% confidence interval, 0.33-0.56), 0.59 L. min(-1). m(-2), and -0.73 to 1.62 L. min(-1). m(-2), respectively. Percentage error was 45%. A significant relationship was found between percent changes in CIPC and CIECOM after fluid challenge (r = 0.42; P = 0.035). Areas under the ROC curves for Delta CIPC and Delta CIECOM to predict fluid responsiveness were 0.72 (95% confidence interval, 0.5-0.88) and 0.81 (95% confidence interval, 0.61-0.94), respectively. Conclusions: ECOM is not interchangeable with pulse contour analysis but seems consistent to monitor cardiac index continuously and could help to predict fluid responsiveness by using passive leg raising.
引用
收藏
页数:9
相关论文
共 31 条
[1]   Comparison of the Endotracheal Cardiac Output Monitor to Thermodilution in Cardiac Surgery Patients [J].
Ball, Timothy R. ;
Culp, Benjamin C. ;
Patel, Vivekkumar ;
Gloyna, David F. ;
Ciceri, David P. ;
Culp, William C., Jr. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (05) :762-766
[2]   Comparing different methods of cardiac output determination: a call for consensus [J].
Bein, B. ;
Renner, J. ;
Scholz, J. ;
Tonner, P. H. .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (08) :710-710
[3]   Fluid responsiveness predicted by noninvasive Bioreactance-based passive leg raise test [J].
Benomar, Brahim ;
Ouattara, Alexandre ;
Estagnasie, Philippe ;
Brusset, Alain ;
Squara, Pierre .
INTENSIVE CARE MEDICINE, 2010, 36 (11) :1875-1881
[4]   Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
ANNALS OF INTERNAL MEDICINE, 2003, 138 (01) :40-44
[7]   Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients [J].
Boulain, T ;
Achard, JM ;
Teboul, JL ;
Richard, C ;
Perrotin, D ;
Ginies, G .
CHEST, 2002, 121 (04) :1245-1252
[8]   Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness A "Gray Zone" Approach [J].
Cannesson, Maxime ;
Le Manach, Yannick ;
Hofer, Christoph K. ;
Goarin, Jean Pierre ;
Lehot, Jean-Jacques ;
Vallet, Benoit ;
Tavernier, Benoit .
ANESTHESIOLOGY, 2011, 115 (02) :231-241
[9]   Arterial Pressure Variation and Goal-Directed Fluid Therapy [J].
Cannesson, Maxime .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (03) :487-497
[10]   Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies [J].
Cavallaro, Fabio ;
Sandroni, Claudio ;
Marano, Cristina ;
La Torre, Giuseppe ;
Mannocci, Alice ;
De Waure, Chiara ;
Bello, Giuseppe ;
Maviglia, Riccardo ;
Antonelli, Massimo .
INTENSIVE CARE MEDICINE, 2010, 36 (09) :1475-1483