Fluid responsiveness predicted by noninvasive Bioreactance-based passive leg raise test

被引:100
作者
Benomar, Brahim [3 ]
Ouattara, Alexandre [2 ]
Estagnasie, Philippe [1 ]
Brusset, Alain [1 ]
Squara, Pierre [1 ]
机构
[1] Clin Ambroise Pare, F-92200 Neuilly Sur Seine, France
[2] Grp Hosp Sud, Serv Anesthesie Reanimat, F-33604 Pessac, France
[3] Univ Paris 06, GH Pitie Salpetriere, AP HP, Dept Anesthesie Reanimat, F-75013 Paris, France
关键词
Cardiac output; Monitoring; Fluid response; CRITICALLY-ILL PATIENTS; RISK SURGICAL-PATIENTS; RANDOMIZED CONTROLLED-TRIAL; CARDIAC-OUTPUT; VOLUME RESPONSIVENESS; ABDOMINAL PRESSURE; BREATHING ACTIVITY; OXYGEN DELIVERY; OPTIMIZATION; SURGERY;
D O I
10.1007/s00134-010-1990-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To study the feasibility of predicting fluid responsiveness (FR) by passive leg raising (PLR) using a Bioreactance-based noninvasive cardiac output monitoring device (NICOM). This prospective, two-center study included 75 consecutive intensive care unit (ICU) adult patients immediately after cardiac surgery. NICOM was used to continuously record cardiac output (CO) at baseline, during a PLR, and then during a 500 ml i.v. rapid colloid infusion. We estimated the precision of NICOM at baseline to derive the least minimum significant change (LMSC) in CO. We studied the predictability of PLR for FR by systematic analysis of different categorizations of PLR and FR, based on percentage change in CO (from 0 to 20%). The LMSC was 8.85%. CO was 4.17 +/- A 1.04 L min(-1) at baseline, 4.38 +/- A 1.14 L min(-1) during PLR, 4.16 +/- A 1.08 L min(-1) upon return to baseline, and 4.85 +/- A 1.41 L min(-1) after fluid infusion. The change in CO following fluid bolus was highly correlated with the change in CO following PLR: y = 0.91x + 4.3, r = 0.77. The Pearson correlation coefficient showed that the best pair of thresholds was found for PLR a parts per thousand yen0% predicting FR a parts per thousand yen0%. Using this pair of thresholds, PLR had 88% sensitivity and 100% specificity for predicting FR. When we restricted the analysis to change in CO > LMSC, the best pair of thresholds was obtained for PLR > 9% predicting FR > 9%. Using this pair of thresholds, PLR sensitivity was reduced to 68% and specificity to 95%. In this specific population of patients, it is clinically valid to use the bioreactance-based NICOM system to predict FR from changes in CO during PLR.
引用
收藏
页码:1875 / 1881
页数:7
相关论文
共 40 条
  • [1] Assessing the accuracy of prediction algorithms for classification: an overview
    Baldi, P
    Brunak, S
    Chauvin, Y
    Andersen, CAF
    Nielsen, H
    [J]. BIOINFORMATICS, 2000, 16 (05) : 412 - 424
  • [2] A RANDOMIZED CLINICAL-TRIAL OF THE EFFECT OF DELIBERATE PERIOPERATIVE INCREASE OF OXYGEN DELIVERY ON MORTALITY IN HIGH-RISK SURGICAL PATIENTS
    BOYD, O
    GROUNDS, RM
    BENNETT, ED
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 270 (22): : 2699 - 2707
  • [3] Monitoring of peri-operative fluid administration by individualized goal-directed therapy
    Bundgaard-Nielsen, M.
    Holte, K.
    Secher, N. H.
    Kehlet, H.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (03) : 331 - 340
  • [4] Hemodynamic effects of passive leg raising: an echocardiographic study in patients with shock
    Caille, Vincent
    Jabot, Julien
    Belliard, Guillaume
    Charron, Cyril
    Jardin, Francois
    Vieillard-Baron, Antoine
    [J]. INTENSIVE CARE MEDICINE, 2008, 34 (07) : 1239 - 1245
  • [5] Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique
    Cecconi, M.
    Dawson, D.
    Grounds, R. M.
    Rhodes, A.
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (03) : 498 - 504
  • [6] Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - with specific reference to the measurement of cardiac output
    Cecconi, Maurizio
    Rhodes, Andrew
    Poloniecki, Jan
    Della Rocca, Giorgio
    Grounds, R. Michael
    [J]. CRITICAL CARE, 2009, 13 (01):
  • [7] Esophageal Doppler-guided fluid management decreases blood lactate levels in multiple-trauma patients:: a randomized controlled trial
    Chytra, Ivan
    Pradl, Richard
    Bosman, Roman
    Pelnar, Petr
    Kasal, Eduard
    Zidkova, Alexandra
    [J]. CRITICAL CARE, 2007, 11 (01):
  • [8] Della Rocca G, 2004, Minerva Anestesiol, V70, P229
  • [9] EFFECTS OF POSITIVE END-EXPIRATORY PRESSURE AND BODY POSITION ON PRESSURE IN THE THORACIC GREAT VEINS
    FESSLER, HE
    BROWER, PG
    SHAPIRO, EP
    PERMUTT, S
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 148 (06): : 1657 - 1664
  • [10] GREENE A, 1986, AM J PHYSIOL, V25, P1288