Monitoring of peri-operative fluid administration by individualized goal-directed therapy

被引:214
作者
Bundgaard-Nielsen, M. [1 ]
Holte, K.
Secher, N. H.
Kehlet, H.
机构
[1] Rigshosp, Dept Anaesthesia, DK-2100 Copenhagen, Denmark
[2] Rigshosp, Sect Surg Pathophysiol, DK-2100 Copenhagen, Denmark
[3] Univ Copenhagen, Hvidovre Hosp, Dept Surg Gastroenterol, Copenhagen, Denmark
关键词
algorithms; fluid therapy; monitoring; treatment outcome;
D O I
10.1111/j.1399-6576.2006.01221.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: In order to avoid peri-operative hypovolaemia or fluid overload, goal-directed therapy with individual maximization of flow-related haemodynamic parameters has been introduced. The objectives of this review are to update research in the area, evaluate the effects on outcome and assess the use of strategies, parameters and monitors for goal-directed therapy. Methods: A MEDLINE search (1966 to 2 October 2006) was performed to identify studies in which a goal-directed therapeutic strategy was used to maximize flow-related haemodynamic parameters in surgical patients, as well as studies referenced from these papers. Furthermore, methods applied in these studies and other monitors with a potential for goal-directed therapy are described. Results: Nine studies were identified pertaining to fluid optimization during the intra- and post-operative period with goal-directed therapy. Seven studies (n = 725) found a reduced hospital stay. Post-operative nausea and vomiting (PONV) and ileus were reduced in three studies and complications were reduced in four studies. Of the monitors that may be applied for goal-directed therapy, only oesophageal Doppler has been tested adequately; however, several other options exist. Conclusion: Goal-directed therapy with the maximization of flow-related haemodynamic variables reduces hospital stay, PONV and complications, and facilitates faster gastrointestinal functional recovery. So far, oesophageal Doppler is recommended, but other monitors are available and call for evaluation.
引用
收藏
页码:331 / 340
页数:10
相关论文
共 71 条
  • [1] Subcutaneous microdialysis for metabolic monitoring in abdominal aortic surgery
    Bahlmann L.
    Wagner K.
    Heringlake M.
    Wirtz Chr.
    Fütterer T.
    Schmucker P.
    Klaus S.
    [J]. Journal of Clinical Monitoring and Computing, 2002, 17 (5) : 309 - 312
  • [2] Pulse contour analysis: should good-looking curves be trusted?
    Berthelsen, P. G.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (09) : 1041 - 1043
  • [3] Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger
    Bogert, LWJ
    van Lieshout, JJ
    [J]. EXPERIMENTAL PHYSIOLOGY, 2005, 90 (04) : 437 - 446
  • [4] Effects of intravenous fluid restriction on postoperative complications: Comparison of two perioperative fluid regimens - A randomized assessor-blinded multicenter trial
    Brandstrup, B
    Tonnesen, H
    Beier-Holgersen, R
    Hjortso, E
    Ording, H
    Lindorff-Larsen, K
    Rasmussen, MS
    Lanng, C
    Wallin, L
    Iversen, LH
    Gramkow, CS
    Okholm, M
    Blemmer, T
    Svendsen, PE
    Rottensten, HH
    Thage, B
    Riis, J
    Jeppesen, IS
    Teilum, D
    Christensen, AM
    Graungaard, B
    Pott, F
    [J]. ANNALS OF SURGERY, 2003, 238 (05) : 641 - 648
  • [5] Flow-related techniques for preoperative goal-directed fluid optimization
    Bundgaard-Nielsen, M.
    Ruhnau, B.
    Secher, N. H.
    Kehlet, H.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (01) : 38 - 44
  • [6] ECHOCARDIOGRAPHIC AND HEMODYNAMIC INDEXES OF LEFT-VENTRICULAR PRELOAD IN PATIENTS WITH NORMAL AND ABNORMAL VENTRICULAR-FUNCTION
    CHEUNG, AT
    SAVINO, JS
    WEISS, SJ
    AUKBURG, SJ
    BERLIN, JA
    [J]. ANESTHESIOLOGY, 1994, 81 (02) : 376 - 387
  • [7] Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery
    Conway, DH
    Mayall, R
    Abdul-Latif, MS
    Gilligan, S
    Tackaberry, C
    [J]. ANAESTHESIA, 2002, 57 (09) : 845 - 849
  • [8] The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults
    Dark, PM
    Singer, M
    [J]. INTENSIVE CARE MEDICINE, 2004, 30 (11) : 2060 - 2066
  • [9] Esophageal Doppler monitor determinations of cardiac output and preload during cardiac operations
    DiCorte, CJ
    Latham, P
    Greilich, PE
    Cooley, MV
    Grayburn, PA
    Jessen, ME
    [J]. ANNALS OF THORACIC SURGERY, 2000, 69 (06) : 1782 - 1786
  • [10] Ejlersen E, 1995, TRANSPLANT P, V27, P3506