The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults

被引:167
作者
Dark, PM
Singer, M
机构
[1] Univ Manchester, Hope Hosp, Dept Intens Care Med, Injury Repair & Rehabil Res Grp, Salford M6 8HD, Lancs, England
[2] UCL, Dept Med, London WC1E 6BT, England
[3] UCL, Wolfson Inst Biomed Res, London WC1E 6BT, England
关键词
cardiac output; trans-esophageal Doppler ultrasonography; esophageal Doppler monitoring;
D O I
10.1007/s00134-004-2430-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine the validity of the esophageal Doppler monitor (EDM) and echo-esophageal Doppler (Echo-ED) in measuring cardiac output in the critically ill. Design: Systematic search of relevant international literature and data synthesis. Search strategy: Literature search (1989-2003) using Ovid interface to Medline, Embase and Cochrane databases aimed at finding studies comparing EDM or Echo-ED cardiac output with that derived from simultaneous pulmonary artery thermodilution (PAC(TD)) with Bland Altman measures of validity. Patients: Critically ill adults in operating departments or intensive care units. Data synthesis: Summary validity measures synthesized from Bland Altman analyses included pooled median bias and the median percentage of clinical agreement (PCA) derived from the limits of agreement. Main results: Eleven validation papers for EDM (21 studies) involving 314 patients and 2,400 paired measurements. The pooled median bias for PAC(TD) versus EDM was 0.19 l/min (range -0.69 to 2.00 l/min) for cardiac output (16 studies), and 0.6% (range 0-2.3%) for changes in cardiac output (5 studies). The pooled median percentage of clinical agreement for PAC(TD) versus EDM was 52% (interquartile range 42-69%) for cardiac output and 86% (interquartile range 55-93%) for changes in cardiac output. These differences in PCA were significant (p=0.03 Mann-Whitney) for bolus PAC(TD) as the clinical "gold standard". We found an insufficient number of studies (2 papers) to assess the validity of Echo-ED. Conclusions:The esophageal Doppler monitor has high validity (no bias and high clinical agreement with pulmonary artery thermodilution) for monitoring changes in cardiac output.
引用
收藏
页码:2060 / 2066
页数:7
相关论文
共 23 条
  • [1] Haemodynamic measurements (Continuous cardiac output and systemic vascular resistance) in critically ill patients: Transoesophageal Doppler versus continuous thermodilution
    Baillard, C
    Cohen, Y
    Fosse, JP
    Karoubi, P
    Hoang, P
    Cupa, M
    [J]. ANAESTHESIA AND INTENSIVE CARE, 1999, 27 (01) : 33 - 37
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Minimally invasive hemodynamic monitoring for the intensivist: Current and emerging technology
    Chaney, JC
    Derdak, S
    [J]. CRITICAL CARE MEDICINE, 2002, 30 (10) : 2338 - 2345
  • [4] Cardiac output during liver transplantation
    Colbert, S
    O'Hanlon, DM
    Duranteau, J
    Ecoffey, C
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (02): : 133 - 138
  • [5] Measurement of cardiac output after cardiac surgery by a new transesophageal Doppler device
    Jaeggi, P
    Hofer, CK
    Klaghofer, R
    Fodor, P
    Genoni, M
    Zollinger, A
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) : 217 - 220
  • [6] A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination
    Keyl, C
    Rodig, G
    Lemberger, P
    Hobbhahn, J
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1996, 13 (02) : 136 - 142
  • [7] CONTINUOUS MEASUREMENT OF CARDIAC-OUTPUT DURING AORTIC CROSS-CLAMPING BY THE ESOPHAGEAL DOPPLER MONITOR ODM-1
    KLOTZ, KF
    KLINGSIEK, S
    SINGER, M
    WENK, H
    ELEFTHERIADIS, S
    KUPPE, H
    SCHMUCKER, P
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 (06) : 655 - 660
  • [8] The peri-operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation - A comparison with the continuous cardiac output monitor
    Krishnamurthy, B
    McMurray, TJ
    McClean, E
    [J]. ANAESTHESIA, 1997, 52 (07) : 624 - 629
  • [9] Laupland KB, 2002, CAN J ANAESTH, V49, P393, DOI 10.1007/BF03017329
  • [10] Oesophageal Doppler monitoring overestimates cardiac output during lumbar epidural anaesthesia
    Leather, HA
    Wouters, PF
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2001, 86 (06) : 794 - 797