A novel system based on a poloxamer PLGA blend as a tetanus toxoid delivery vehicle

被引:84
作者
Tobío, M
Nolley, J
Guo, YY
McIver, J
Alonso, MJ [1 ]
机构
[1] Sch Pharm, Dept Pharm & Pharmaceut Technol, Santiago De Compostela 15706, Spain
[2] Massachusetts Biol Labs, Boston, MA 02130 USA
关键词
poloxamer PLGA microspheres; vaccine delivery; tetanus toxoid; immune response;
D O I
10.1023/A:1018820507379
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose. Previous work on the encapsulation of proteins and antigens in poly(lactic-co-glycolic acid) (PLGA) microspheres has led to the conclusion that microencapsulated antigens are frequently inactivated due to their interaction with the polymer. To improve the compatibility of the antigen with the polymer, we have devised a novel microencapsulated system consisting of a blend of PLGA 50:50 and poloxamer 188 (Pluronic(R) F68) and applied it to the delivery of tetanus antigen. Methods. Tetanus toroid was encapsulated in microspheres containing different amounts of poloxamer using an anhydrous procedure based on an oil-in-oil solvent extraction process. The compatibility of the polymers was studied by Fourier transform infrared (FT-IR) spectroscopy. Microspheres were assayed in vitro and in vivo for their ability to deliver active antigen for extended periods of time. Results. Analysis by FT-IR spectroscopy evidenced the miscibility of both polymers by a hydrogen bonding mechanism. In vitro release studies revealed that microspheres containing poloxamer released antigenically active TT, in a pulsatile manner, for up to 50 days. In addition, it was observed that the intensity and duration of the pulses were dependent on both poloxamer content and TT loading in the microspheres. The in vivo evaluation of this new system showed that the neutralizing antibodies elicited by the TT encapsulated in poloxamer-PLGA microspheres were considerably higher and more prolonged than those obtained after administration of the aluminum phosphate-adsorbed toroid. Conclusions. These results indicate the importance of devising new microencapsulation approaches specially adapted for preserving the activity of protein antigens incorporated within PLGA microspheres.
引用
收藏
页码:682 / 688
页数:7
相关论文
共 24 条
[1]   BIODEGRADABLE MICROSPHERES AS CONTROLLED-RELEASE TETANUS TOXOID DELIVERY SYSTEMS [J].
ALONSO, MJ ;
GUPTA, RK ;
MIN, C ;
SIBER, GR ;
LANGER, R .
VACCINE, 1994, 12 (04) :299-306
[2]   DETERMINANTS OF RELEASE RATE OF TETANUS VACCINE FROM POLYESTER MICROSPHERES [J].
ALONSO, MJ ;
COHEN, S ;
PARK, TG ;
GUPTA, RK ;
SIBER, GR ;
LANGER, R .
PHARMACEUTICAL RESEARCH, 1993, 10 (07) :945-953
[3]  
ALONSO MJ, 1996, P INT S REL BIOACT M, V23, P825
[4]   Stabilization of tetanus toxoid in poly(DL-lactic-co-glycolic acid) microspheres for the controlled release of antigen [J].
Chang, AC ;
Gupta, RK .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1996, 85 (02) :129-132
[5]   CONTROLLED DELIVERY SYSTEMS FOR PROTEINS BASED ON POLY(LACTIC GLYCOLIC ACID) MICROSPHERES [J].
COHEN, S ;
YOSHIOKA, T ;
LUCARELLI, M ;
HWANG, LH ;
LANGER, R .
PHARMACEUTICAL RESEARCH, 1991, 8 (06) :713-720
[6]   PARAMETERS AFFECTING THE IMMUNOGENICITY OF MICROENCAPSULATED TETANUS TOXOID [J].
ESPARZA, I ;
KISSEL, T .
VACCINE, 1992, 10 (10) :714-720
[7]  
GANDER B, 1993, P INT S CONTROL REL, V20, P65
[8]  
Gupta R.K., 1995, VACCINE DESIGN SUBUN, P229
[9]   THE TITRATION OF TETANUS ANTITOXIN .4. STUDIES ON THE SENSITIVITY AND REPRODUCIBILITY OF THE TOXIN NEUTRALIZATION TEST [J].
GUPTA, RK ;
MAHESHWARI, SC ;
SINGH, H .
JOURNAL OF BIOLOGICAL STANDARDIZATION, 1985, 13 (02) :143-149
[10]   Chronic local tissue reactions, long term immunogenicity and immunologic priming of mice and guinea pigs to tetanus toxoid encapsulated in biodegradable polymer microspheres composed of poly lactide-co-glycolide polymers [J].
Gupta, RK ;
Alroy, J ;
Alonso, MJ ;
Langer, R ;
Siber, GR .
VACCINE, 1997, 15 (16) :1716-1723