High-resolution breath-hold contrast-enhanced MR angiography of the entire carotid circulation

被引:29
作者
Carr, JC
Ma, J
Desphande, V
Pereles, S
Laub, G
Finn, JP
机构
[1] Northwestern Univ, Dept Radiol, Med Sch, Chicago, IL 60611 USA
[2] Northwestern Univ, Sch Med, Dept Biomed Engn, Chicago, IL 60611 USA
[3] Siemens Res & Dev, Chicago, IL 60611 USA
关键词
D O I
10.2214/ajr.178.3.1780543
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the effect of breathing on image quality of the aortic arch and carotid vessels during contrast-enhanced MR angiography and to show that high-resolution breath-hold contrast-enhanced MR angiography combined with a timing-bolus technique can produce high-quality images of the entire carotid circulation. MATERIALS AND METHODS. Forty patients underwent high-resolution contrast- J enhanced MR angiography on a 1.5-T Magnctom Symphony. A coronal three-dimensional (3D) gradient-echo sequence (TR/TE, 4.36/1.64; flip angle, 25degrees) with asymmetric k-space ac- quisition was used. The 136 x 512 matrix yielded voxel sizes of 1.33 x 0.64 x 1.0 nun. A timing-bolus acquisition, orientated in the coronal plane to include the aortic arch, was obtained initially during free-breathing. Twenty milliliters of gadopenetate dimeglumine was injected at 2 mL/sec. Unenhanced and enhanced 3D volumes were recorded. A subtracted 3D set was calculated and subjected to a maximum-intensity-projection algorithm. Half of the patients held their breath during angiography and the other half did not. Aortic arch motion was measured on the timing-bolus acquisition as the distance moved by a single pixel in both the x and y directions. Maximum-intensity-projection MR images were assessed independently by two observers, and vessel sharpness was scored on a scale of 1-5. Sharpness was also assessed quantitatively by generating a signal intensity profile across the aortic arch vessel wall and calculating the average of the upslope and downslope at full-width half maximum. Visualization of carotid branch vessels was scored on a scale of 0-5, and venous contamination was scored on a scale of 0-3. RESULTS. Average in-plane aortic arch movement was 10.3 mm. in the x direction and 8.7 nun in the y direction. Quantitative and qualitative sharpness of the aortic arch and great vessel origins was better (p < 0.05) during breath-holding than during non-breath-holding. No difference in the sharpness of the carotid vessels was noted between the two groups. Carotid branch vessels were well visualized from the aortic arch to the intracerebral circulation. The average venous contamination score was 0.56. CONCLUSION. Breath-holding greatly improves the sharpness of the aortic arch and great vessel origins but has no effect on visualization of the carotid vessels. High-resolution breath-hold contrast-enhanced MR angiography can produce high-quality, artifact-free images of the entire carotid circulation from the aortic arch to the intracerebral circulation.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 34 条
[1]  
Aoki S, 2000, AM J NEURORADIOL, V21, P381
[2]   High-resolution magnetic resonance angiography of the internal carotid artery: 2D vs 3D TOF in stenotic disease [J].
Carriero, A ;
Scarabino, T ;
Magarelli, N ;
Marano, R ;
Ambrosini, R ;
Salvolini, U ;
Bonomo, L .
EUROPEAN RADIOLOGY, 1998, 8 (08) :1370-1372
[3]   Improved imaging of carotid artery bifurcation using helical computed tomographic angiography [J].
Cinat, ME ;
Pham, H ;
Vo, D ;
Gordon, I ;
Wilson, SE .
ANNALS OF VASCULAR SURGERY, 1999, 13 (02) :178-183
[4]   ROLE OF DOPPLER US IN SCREENING FOR CAROTID ATHEROSCLEROTIC DISEASE [J].
DERDEYN, CP ;
POWERS, WJ ;
MORAN, CJ ;
CROSS, DT ;
ALLEN, BT .
RADIOLOGY, 1995, 197 (03) :635-643
[5]  
HEISERMAN JE, 1994, AM J NEURORADIOL, V15, P1401
[6]   CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY [J].
HEISERMAN, JE ;
DRAYER, BP ;
FRAM, EK ;
KELLER, PJ ;
BIRD, CR ;
HODAK, JA ;
FLOM, RA .
RADIOLOGY, 1992, 182 (03) :761-768
[7]   CAROTID-ARTERY - PROSPECTIVE BLINDED COMPARISON OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY AND DUPLEX US [J].
HUSTON, J ;
LEWIS, BD ;
WIEBERS, DO ;
MEYER, FB ;
RIEDERER, SJ ;
WEAVER, AL .
RADIOLOGY, 1993, 186 (02) :339-344
[8]   Carotid arteries: Maximizing arterial to venous contrast in fluoroscopically triggered contrast-enhanced MR angiography with elliptic centric view ordering [J].
Huston, J ;
Fain, SB ;
Riederer, SJ ;
Wilman, AH ;
Bernstein, MA ;
Busse, RF .
RADIOLOGY, 1999, 211 (01) :265-273
[9]   Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography [J].
Kim, JK ;
Farb, RI ;
Wright, GA .
RADIOLOGY, 1998, 206 (01) :283-289
[10]   Contrast-enhanced MR angiography of the supra-aortic vessels in 24 seconds: a feasibility study [J].
Kollias, SS ;
Binkert, CA ;
Ruesch, S ;
Valavanis, A .
NEURORADIOLOGY, 1999, 41 (06) :391-400