Hemodynamics in coronary arteries with overlapping stents

被引:52
作者
Rikhtegar, Farhad [1 ]
Wyss, Christophe [2 ]
Stok, Kathryn S. [3 ]
Poulikakos, Dimos [1 ]
Mueller, Ralph [3 ]
Kurtcuoglu, Vartan [1 ,4 ]
机构
[1] ETH, Dept Mech & Proc Engn, Lab Thermodynam Emerging Technol, Zurich, Switzerland
[2] Univ Zurich Hosp, Clin Cardiol, CH-8091 Zurich, Switzerland
[3] ETH, Dept Hlth Sci & Technol, Inst Biomech, Zurich, Switzerland
[4] Univ Zurich, Inst Physiol, Interface Grp, CH-8057 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
Stent overlap; Thrombosis; Hemodynamics; Wall shear stress; Restenosis; WALL SHEAR-STRESS; SIROLIMUS-ELUTING STENTS; SELF-EXPANDING STENTS; ENDOTHELIAL SHEAR; BALLOON ANGIOPLASTY; POOLED ANALYSIS; BARE-METAL; HIGH-RISK; RESTENOSIS; IMPLANTATION;
D O I
10.1016/j.jbiomech.2013.10.048
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Coronary artery stenosis is commonly treated by stent placement via percutaneous intervention, at times requiring multiple stents that may overlap. Stent overlap is associated with increased risk of adverse clinical outcome. While changes in local blood flow are suspected to play a role therein, hemodynamics in arteries with overlapping stents remain poorly understood. In this study we analyzed six cases of partially overlapping stents, placed ex vivo in porcine left coronary arteries and compared them to five cases with two non-overlapping stents. The stented vessel geometries were obtained by micro-computed tomography of corrosion casts. Flow and shear stress distribution were calculated using computational fluid dynamics. We observed a significant increase in the relative area exposed to low wall shear stress (WSS < 0.5 Pa) in the overlapping stent segments compared both to areas without overlap in the same samples, as well as to non-overlapping stents. We further observed that the configuration of the overlapping stent struts relative to each other influenced the size of the low WSS area: positioning of the struts in the same axial location led to larger areas of low WSS compared to alternating struts. Our results indicate that the overlap geometry is by itself sufficient to cause unfavorable flow conditions that may worsen clinical outcome. While stent overlap cannot always be avoided, improved deployment strategies or stent designs could reduce the low WSS burden. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 54 条
[21]   Analysis of 1-year clinical outcomes in the SIRIUS trial - A randomized trial of a sirolimus-eluting stent versus a standard stent in patients at high risk for coronary restenosis [J].
Holmes, DR ;
Leon, MB ;
Moses, JW ;
Popma, JJ ;
Cutlip, D ;
Fitzgerald, PJ ;
Brown, C ;
Fischell, T ;
Wong, SC ;
Midei, M ;
Snead, D ;
Kuntz, RE .
CIRCULATION, 2004, 109 (05) :634-640
[22]   Coronary artery flow measurement using navigator echo gated phase contrast magnetic resonance velocity mapping at 3.0 T [J].
Johnson, Kevin ;
Sharma, Puneet ;
Oshinski, John .
JOURNAL OF BIOMECHANICS, 2008, 41 (03) :595-602
[23]   Influence of lesion length on restenosis after coronary stent placement [J].
Kastrati, A ;
Elezi, S ;
Dirschinger, J ;
Hadamitzky, M ;
Neumann, FJ ;
Schömig, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (12) :1617-1622
[24]  
Kastrati A, 2001, CIRCULATION, V103, P2816
[25]   Periprocedural and late consequences of overlapping Cypher sirolimus-eluting stents - Pooled analysis of five clinical trials [J].
Kereiakes, Dean J. ;
Wang, Hong ;
Popma, Jeffrey J. ;
Kuntz, Richard E. ;
Donohoe, Dennis J. ;
Schofer, Joachim ;
Schampaert, Erick ;
Meier, Bernhard ;
Leon, Martin B. ;
Moses, Jeffrey W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :21-31
[26]   Choosing the optimal wall shear parameter for the prediction of plaque location-A patient-specific computational study in human right coronary arteries [J].
Knight, Joseph ;
Olgac, Ufuk ;
Saur, Stefan C. ;
Poulikakos, Dimos ;
Marshall, William, Jr. ;
Cattin, Philippe C. ;
Alkadhi, Hatem ;
Kurtcuoglu, Vartan .
ATHEROSCLEROSIS, 2010, 211 (02) :445-450
[27]   Stent Thrombogenicity Early in High-Risk Interventional Settings Is Driven by Stent Design and Deployment and Protected by Polymer-Drug Coatings [J].
Kolandaivelu, Kumaran ;
Swaminathan, Rajesh ;
Gibson, William J. ;
Kolachalama, Vijaya B. ;
Nguyen-Ehrenreich, Kim-Lien ;
Giddings, Virginia L. ;
Coleman, Leslie ;
Wong, Gee K. ;
Edelman, Elazer R. .
CIRCULATION, 2011, 123 (13) :1400-1409
[28]   Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models [J].
LaDisa, JF ;
Olson, LE ;
Guler, I ;
Hettrick, DA ;
Kersten, JR ;
Warltier, DC ;
Pagel, PS .
JOURNAL OF APPLIED PHYSIOLOGY, 2005, 98 (03) :947-957
[29]   Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling [J].
LaDisa, John F., Jr. ;
Olson, Lars E. ;
Douglas, Hettrick A. ;
Warltier, David C. ;
Kersten, Judy R. ;
Pagel, Paul S. .
BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
[30]   Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography [J].
Matsumoto, Daisuke ;
Shite, Junya ;
Shinke, Toshiro ;
Otake, Hiromasa ;
Tanino, Yusuke ;
Ogasawara, Daisuke ;
Sawada, Takahiro ;
Paredes, Oscar Luis ;
Hirata, Ken-ichi ;
Yokoyama, Mitsuhiro .
EUROPEAN HEART JOURNAL, 2007, 28 (08) :961-967