Improved 2D time-of-flight angiography using a radial-line k-space acquisition

被引:17
作者
Nielsen, HTC
Olcott, EW
Nishimura, DG
机构
[1] STANFORD UNIV,DEPT ELECT ENGN,STANFORD,CA 94305
[2] STANFORD UNIV,DEPT RADIOL,STANFORD,CA 94305
关键词
radial lines; flow imaging; time-of-flight angiography; magnetic resonance imaging;
D O I
10.1002/mrm.1910370224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For flow imaging applications, radial-line k-space acquisition methods offer advantages over conventional 2DFT methods. Specifically, radial-line acquisition methods mitigate artifacts resulting from pulsatile flow while offering a potential reduction in scan times. In this paper, radial-line and 2DFT acquisitions are compared in a two-dimensional time-of-flight angiography sequence. The twisting radial-line (TwiRL) trajectory, a variant of 2D projection reconstruction, is used to represent the family of radial-line trajectories. In both phantom and in vivo studies, the TwiRL images demonstrate improved vessel depiction including a more uniform signal intensity and better delineation of the vasculature in comparison with images obtained via the 2DFT method.
引用
收藏
页码:285 / 291
页数:7
相关论文
共 21 条
[1]   PULSATILE FLOW ARTIFACTS IN 2-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY - INITIAL STUDIES IN ELASTIC MODELS OF HUMAN CAROTID ARTERIES [J].
BUXTON, RB ;
KERBER, CW ;
FRANK, LR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04) :625-636
[2]   POPLITEAL AND TIBIOPERONEAL ARTERIES - FEASIBILITY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY AND PHASE-VELOCITY MAPPING [J].
CAPUTO, GR ;
MASUI, T ;
GOODING, GAW ;
CHANG, JM ;
HIGGINS, CB .
RADIOLOGY, 1992, 182 (02) :387-392
[3]  
GRAAF RGD, 1992, MAGN RESON IMAGING, V10, P25
[4]   TWISTING RADIAL LINES WITH APPLICATION TO ROBUST MAGNETIC-RESONANCE-IMAGING OF IRREGULAR FLOW [J].
JACKSON, JI ;
NISHIMURA, DG ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (01) :128-139
[5]   SELECTION OF A CONVOLUTION FUNCTION FOR FOURIER INVERSION USING GRIDDING [J].
JACKSON, JI ;
MEYER, CH ;
NISHIMURA, DG ;
MACOVSKI, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :473-478
[6]   MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS [J].
KELLER, PJ ;
DRAYER, BP ;
FRAM, EK ;
WILLIAMS, KD ;
DUMOULIN, CL ;
SOUZA, SP .
RADIOLOGY, 1989, 173 (02) :527-532
[7]   FAST SPIRAL CORONARY-ARTERY IMAGING [J].
MEYER, CH ;
HU, BS ;
NISHIMURA, DG ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :202-213
[8]  
NEILSEN HTC, 1994, P SMR 2 ANN M, P942
[9]  
NEILSEN HTC, 1996, P 4 ANN M ISMRM, P243
[10]   A VELOCITY K-SPACE ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR AND SPIRAL IMAGING [J].
NISHIMURA, DG ;
IRARRAZABAL, P ;
MEYER, CH .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) :549-556