X-ray calibrated tunneling system utilizing a dimensionally stable nanometer positioner

被引:23
作者
Miller, JA
Hocken, R
Smith, ST
Harb, S
机构
[1] Precision Engineering Laboratory, Univ. of North Carolina at Charlotte, Charlotte, NC
[2] Ctr. Nanotechnology Microengineering, University of Warwick, Coventry
[3] Precision Engineering Laboratory, Univ. of North Carolina at Charlotte, Charlotte, NC 28223
[4] Precision Engineering Laboratory, UNC-Charlotte, Charlotte
[5] School of Engineering, Coventry University, Coventry CV1 5FB, Priori Street
来源
PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING | 1996年 / 18卷 / 2-3期
关键词
nanotechnology; metrology; x-ray interferometry; electron tunneling; monolithic flexures; nanometer positioning; screw-wedge-lever;
D O I
10.1016/0141-6359(96)00037-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To determine to what extent tunneling probes can be used for metrology or as position-sensitive transducers on the atomic scale, accurate characterization of tunneling current as a function of distance must be ascertained. This report describes a system for making such characterizations and observing their repeatability in air. Also, it is often necessary to position two objects to within nanometers in order to perform precision measurements. Included in the narrative, a dimensionally stable screw-wedge-lever system is described for manually moving a funneling probe to within 15 nm of a conducting surface. The conducting surface is translated via a magnetically actuated single crystal flexure system previously calibrated through direct x-ray interferometry over a 20-nm range. This limited calibration range dictated dimensional positioning below 15 nm. Also, funneling current measurements demanded dimensional stability below one nanometer. The complete system is demonstrated to hold the relative probe-surface separation to within 1 nm over a 15-minute duration. Also, the vibrational resonance of the structure is determined using the power spectrum analysis during electron tunneling. Resulting data using platinum, palladium, and silver tips in conjunction with a carbon surface show that current-displacement values vary from run to run with a positional difference of up to 1 nm for a given current. These variations suggest limitations for using tunneling probes in air to perform angstrom metrology.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 12 条
[1]   VACUUM TUNNELING PROBE - A NONRECIPROCAL, REDUCED-BACK-ACTION TRANSDUCER [J].
BOCKO, MF ;
STEPHENSON, KA ;
KOCH, RH .
PHYSICAL REVIEW LETTERS, 1988, 61 (06) :726-729
[3]  
Chetwynd D. G., 1991, Measurement and Control, V24, P52
[4]  
Chetwynd D. G., 1991, Nanotechnology, V2, P1, DOI 10.1088/0957-4484/2/1/001
[5]   SCANNING TUNNELING MICROSCOPY [J].
HANSMA, PK ;
TERSOFF, J .
JOURNAL OF APPLIED PHYSICS, 1987, 61 (02) :R1-R23
[6]  
MILLER JA, 1994, THESIS U WARWICK COV
[7]  
*NASA, 1994, NASA TECH BRIEFS, P36
[8]  
QUATE CF, 1986, Patent No. 4575822
[10]   AN OPTIMIZED MAGNET-COIL FORCE ACTUATOR AND ITS APPLICATION TO PRECISION ELASTIC MECHANISMS [J].
SMITH, ST ;
CHETWYND, DG .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1990, 204 (04) :243-253