Prospective study on serum metal levels in patients with metal-on-metal lumbar disc arthroplasty

被引:23
作者
Gornet, Matthew F. [1 ]
Burkus, J. K. [2 ]
Harper, M. L. [3 ]
Chan, F. W. [4 ]
Skipor, A. K. [5 ]
Jacobs, J. J. [5 ]
机构
[1] Orthoped Ctr St Louis, Spine Res Ctr, St Louis, MO 63017 USA
[2] Hughston Clin, Columbus, GA 31908 USA
[3] AF Solut, Medtron, Minneapolis, MN 55112 USA
[4] Covidien, Resp & Monitoring Solut, Boulder, CO 80301 USA
[5] Rush Univ, Med Ctr, Chicago, IL 60612 USA
关键词
Lumbar degenerative disc disease; Disc arthroplasty; Metal ions; Chromium; Cobalt; Metal-on-metal; TOTAL HIP-ARTHROPLASTY; INVESTIGATIONAL-DEVICE-EXEMPTION; RANDOMIZED-CLINICAL-TRIAL; MEDTRONIC SOFAMOR DANEK; FOLLOW-UP; RESURFACING ARTHROPLASTY; SPINAL ARTHRODESIS; CHROMIUM IONS; MAVERICK DISC; COBALT;
D O I
10.1007/s00586-012-2581-8
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Metal-on-metal total disc replacement is a recent alternative treatment for degenerative disc disease. Wear and corrosion of these implants can lead to local and systemic transport of metal debris. This prospective longitudinal study examined the serum chromium and cobalt levels in 24 patients with cobalt-chromium alloy metal-on-metal lumbar disc replacements. Serum was assayed for chromium (Cr) and cobalt (Co) using high-resolution inductively-coupled plasma-mass spectrometry. Detection limits were 0.015 ng/mL for Cr and 0.04 ng/mL for Co. Median serum Co levels at pre-op, 3, 6, 12, 24, and 36-months post-op were 0.10, 1.03, 0.96, 0.98, 0.67, and 0.52 ng/mL, respectively. Median serum Cr levels were 0.06, 0.49, 0.65, 0.43, 0.52, and 0.50 ng/mL, respectively. In general, these results indicated that serum Co and Cr levels are elevated at all postoperative time points and are of the same order of magnitude as those observed in well-functioning metal-on-metal surface replacements of the hip and in metal-on-metal total hip replacements at similar postoperative time points.
引用
收藏
页码:741 / 746
页数:6
相关论文
共 44 条
[1]
Clinical and Radiographic Results of Metal-on-Metal Hip Resurfacing with a Minimum Ten-Year Follow-up [J].
Amstutz, Harlan C. ;
Le Duff, Michel J. ;
Campbell, Patricia A. ;
Gruen, Thomas A. ;
Wisk, Lauren E. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (16) :2663-2671
[2]
[Anonymous], 153708 ASTM
[3]
How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? [J].
Back, DL ;
Young, AA ;
Shimmin, AJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) :177-181
[4]
The artificial disc: Theory, design and materials [J].
Bao, QB ;
McCullen, GM ;
Higham, PA ;
Dumbleton, JH ;
Yuan, HA .
BIOMATERIALS, 1996, 17 (12) :1157-1167
[5]
A Granulomatous Mass Surrounding a Maverick Total Disc Replacement Causing Iliac Vein Occlusion and Spinal Stenosis A Case Report [J].
Berry, Michael R. ;
Peterson, Brian G. ;
Alander, Dirk H. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (05) :1242-1245
[6]
Metal ion levels in patients with a lumbar metal-on-metal total disc replacement SHOULD WE BE CONCERNED? [J].
Bisseling, P. ;
Zeilstra, D. J. ;
Hol, A. M. ;
van Susante, J. L. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (07) :949-954
[7]
Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Grübl, A ;
Jankovsky, R ;
Meisinger, V ;
Lehr, S ;
Gottsauner-Wolf, F .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :66-70
[8]
Metal ion levels in patients with stainless steel spinal instrumentation [J].
Bruce, I. ;
Swanson, Cheryl E. .
SPINE, 2007, 32 (18) :1963-1968
[9]
Clark M, 2012, T 58 ANN M ORTH RES
[10]
Chromium Ion Release From Stainless Steel Pediatric Scoliosis Instrumentation [J].
Cundy, Thomas P. ;
Delaney, Christopher L. ;
Rackham, Matthew D. ;
Antoniou, Georgia ;
Oakley, Andrew P. ;
Freeman, Brian J. C. ;
Sutherland, Leanne M. ;
Cundy, Peter J. .
SPINE, 2010, 35 (09) :967-974