How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?

被引:128
作者
Back, DL [1 ]
Young, AA [1 ]
Shimmin, AJ [1 ]
机构
[1] Melbourne Orthopaed Grp, Melbourne, Vic 3181, Australia
关键词
D O I
10.1097/01.blo.0000166901.85323.5d
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We prospectively monitored changes in serum cobalt and chromium levels after a new generation metal-on-metal hip resurfacing and the affect on renal function. Levels were measured using inductively coupled plasma mass spectrometry and atomic absorption spectrometry, preoperatively then sequentially at 3, 6, 9, 12, and 24 months. For serum cobalt, there was an initial increase to a peak level at 6 months, followed by a gradual decline during the next 15 months. A similar trend was observed in serum chromium, although the peak level occurred slightly later, at 9 months. There was no adverse affect on renal function during the 2-year study period. All implants were functioning well, with no radiographic evidence of loosening. These levels will continue to be monitored to establish when minimum metal ion levels are reached.
引用
收藏
页码:177 / 181
页数:5
相关论文
共 34 条
[1]
Amstutz H. C., 1996, CLIN ORTHOP S, V329, P11
[2]
Metal-on-metal hybrid surface arthroplasty:: Two to six-year follow-up study [J].
Amstutz, HC ;
Beaulé, PE ;
Dorey, FJ ;
Le Duff, MJ ;
Campbell, PA ;
Gruen, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :28-39
[3]
RESORPTION OF BONE BY INFLAMMATORY CELLS DERIVED FROM THE JOINT CAPSULE OF HIP ARTHROPLASTIES [J].
ATHANASOU, NA ;
QUINN, J ;
BULSTRODE, CJK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :57-62
[4]
THE MCKEE-FARRAR HIP-ARTHROPLASTY - A LONG-TERM STUDY [J].
AUGUST, AC ;
ALDAM, CH ;
PYNSENT, PB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (04) :520-527
[5]
A STUDY OF IMPLANT FAILURE IN THE WAGNER RESURFACING ARTHROPLASTY [J].
BELL, RS ;
SCHATZKER, J ;
FORNASIER, VL ;
GOODMAN, SB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (08) :1165-1175
[6]
Serum cobalt levels after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
Gottsauner-Wolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2168-2173
[7]
Elevated serum cobalt with metal-on-metal articulating surfaces [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
GottsaunerWolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :316-321
[8]
SENSITIVITY TO METAL AS A POSSIBLE CAUSE OF STERILE LOOSENING AFTER COBALT-CHROMIUM TOTAL HIP-REPLACEMENT ARTHROPLASTY [J].
BROWN, GC ;
LOCKSHIN, MD ;
SALVATI, EA ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (02) :164-168
[9]
WIDESPREAD DISSEMINATION OF METAL DEBRIS FROM IMPLANTS [J].
CASE, CP ;
LANGKAMER, VG ;
JAMES, C ;
PALMER, MR ;
KEMP, AJ ;
HEAP, PF ;
SOLOMON, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :701-712
[10]
Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty [J].
Clarke, MT ;
Lee, PTH ;
Arora, A ;
Villar, RN .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (06) :913-917