The influence of data pre-processing in the pattern recognition of excipients near-infrared spectra

被引:210
作者
Candolfi, A
De Maesschalck, R
Jouan-Rimbaud, D
Hailey, PA
Massart, DL
机构
[1] Free Univ Brussels, ChemoAC, B-1090 Brussels, Belgium
[2] Pfizer Ltd, Cent Res, Analyt Res & Dev, Sandwich CT13 9NJ, Kent, England
关键词
pharmaceutical excipients; NIR spectroscopy; pre-processing; pattern recognition; positive identification;
D O I
10.1016/S0731-7085(99)00125-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effect of data pre-processing (no pre-processing, offset correction, de-trending, standard normal variate transformation (SNV), SNV + de-trending, multiplicative scatter correction, first and second derivative transformation after smoothing) on the identification of ten pharmaceutical excipients is investigated. Four pattern recognition methods are tested in the study, namely the Mahalanobis distance method, the SIMCA residual variance method, the wavelength distance method and a method based on triangular potential functions. The performance of the 32 method combinations is evaluated on the basis of two NIR data sets. The first one, measured in 1994, is used to build the classification models, the second, measured from 1994-1997, is used to assess the quality of the models. The best approach for the given data sets is the wavelength distance method combined with de-trending, a simple baseline correction method. More general recommendations for pre-processing excipient NIR data and for choosing an appropriate classification method are given. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:115 / 132
页数:18
相关论文
共 39 条
  • [1] STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA
    BARNES, RJ
    DHANOA, MS
    LISTER, SJ
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (05) : 772 - 777
  • [2] Standardisation of near-infrared spectrometric instruments: A review
    Bouveresse, E
    Massart, DL
    [J]. VIBRATIONAL SPECTROSCOPY, 1996, 11 (01) : 3 - 15
  • [3] Comparison of classification approaches applied to NIR-spectra of clinical study lots
    Candolfi, A
    Wu, W
    Massart, DL
    Heuerding, S
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (08) : 1329 - 1347
  • [4] Identification of pharmaceutical excipients using NIR spectroscopy and SIMCA
    Candolfi, A
    De Maesschalck, R
    Massart, DL
    Hailey, PA
    Harrington, ACE
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (06) : 923 - 935
  • [5] COOMANS D, 1981, ANAL CHIM ACTA-COMP, V5, P225
  • [6] COOMANS D, 1981, ANAL CHIM ACTA-COMP, V5, P215
  • [7] Coomans D., 1986, POTENTIAL PATTERN RE
  • [8] CORTI P, 1992, PHARM ACTA HELV, V67, P57
  • [9] Decision criteria for soft independent modelling of class analogy applied to near infrared data
    De Maesschalck, R
    Candolfi, A
    Massart, DL
    Heuerding, S
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 47 (01) : 65 - 77
  • [10] A NEAR-INFRARED REFLECTANCE ANALYSIS METHOD FOR THE NONINVASIVE IDENTIFICATION OF FILM-COATED AND NON-FILM-COATED, BLISTER-PACKED TABLETS
    DEMPSTER, MA
    MACDONALD, BF
    GEMPERLINE, PJ
    BOYER, NR
    [J]. ANALYTICA CHIMICA ACTA, 1995, 310 (01) : 43 - 51