Distortion of intravascular ultrasound images because of nonuniform angular velocity of mechanical-type transducers

被引:29
作者
Kimura, BJ
Bhargava, V
Palinski, W
Russo, RJ
DeMaria, AN
机构
[1] UNIV CALIF SAN DIEGO, DIV CARDIOL, SAN DIEGO, CA 92103 USA
[2] UNIV CALIF SAN DIEGO, DEPT MED, SAN DIEGO, CA 92103 USA
[3] VET ADM MED CTR, SAN DIEGO, CA 92161 USA
[4] SCRIPPS CLIN & RES FDN, SAN DIEGO, CA USA
关键词
D O I
10.1016/S0002-8703(96)90429-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to quantify nonuniform rotation in a current mechanical intravascular ultrasound (IVUS) instrument and its effect on are, area, and diameter measurements. The accurate reconstruction of IVUS two-dimensional images is dependent on uniform rotation of the catheter tip. Prior investigations suggested that bends in the catheter driveshaft may be responsible for poor torque transmission, nonuniform rotation, and consequent errors in IVUS measurements. Eight 30 MHz mechanically driven IVUS catheters were evaluated in a model simulating the catheter course through the aorta and coronary ostium in a clinical study. Angular velocity and posiion profiles of the transducer, image angle, and diameter and area measurement errors were obtained from each catheter by imaging a vascular phantom with eight equispaced echogenic markers from concentric and eccentric positions. Six catheters also were tested for comparison in a simple curvature model. Rotational error was found in all catheters tested and worsened in the aortic model. Maximal angular error, defined as the largest angle between actual and presumed transducer direction, increased when measured in the aortic model as compared with the simple curvature model (17 +/- 12 degrees to 45 +/- 25 degrees; p<0.05). Angles of 45 degrees were misrepresented with a mean range of values of 26 to 63 degrees. With eccentric catheter placement, area and diameters had average maximal absolute errors of 26% +/- 7.8% and 23% +/- 10%, respectively. In conclusion, nonuniform rotation of mechanical IVUS transducers constitutes a significant potential source of error in IVUS measurement of arcs of calcification, and lumen shape, area, and diameter.
引用
收藏
页码:328 / 336
页数:9
相关论文
共 32 条
[1]  
ANDERSON MH, 1992, BRIT HEART J, V68, P276
[2]   INVITRO AND INVIVO INTRAVASCULAR ULTRASOUND IMAGING [J].
BARTORELLI, AL ;
NEVILLE, RF ;
KEREN, G ;
POTKIN, BN ;
ALMAGOR, Y ;
BONNER, RF ;
GESSERT, JM ;
LEON, MB .
EUROPEAN HEART JOURNAL, 1992, 13 (01) :102-108
[3]   3-DIMENSIONAL INTRAVASCULAR ULTRASOUND IMAGING OF NORMAL AND DISEASED CANINE AND HUMAN ARTERIES [J].
CAVAYE, DM ;
WHITE, RA ;
KOPCHOK, GE ;
MUELLER, MP ;
MASELLY, MJ ;
TABBARA, MR .
JOURNAL OF VASCULAR SURGERY, 1992, 16 (04) :509-519
[4]  
CHAE JS, 1992, J AM SOC ECHOCARDIOG, V5, P557
[5]   INTRAVASCULAR ULTRASOUND IMAGING - A CURRENT PERSPECTIVE [J].
COY, KM ;
MAURER, G ;
SIEGEL, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (07) :1811-1823
[6]   ASSESSMENT OF CORONARY VASOMOTION BY INTRACORONARY ULTRASOUND [J].
DUPOUY, P ;
GESCHWIND, HJ ;
PELLE, G ;
GALLOT, D ;
DUBOISRANDE, JL .
AMERICAN HEART JOURNAL, 1993, 126 (01) :76-85
[7]   INTRAVASCULAR ULTRASOUND IMAGING OF CORONARY-ARTERIES - IS 3 LAYERS THE NORM [J].
FITZGERALD, PJ ;
STGOAR, FG ;
CONNOLLY, AJ ;
PINTO, FJ ;
BILLINGHAM, ME ;
POPP, RL ;
YOCK, PG .
CIRCULATION, 1992, 86 (01) :154-158
[8]   CONTRIBUTION OF LOCALIZED CALCIUM DEPOSITS TO DISSECTION AFTER ANGIOPLASTY - AN OBSERVATIONAL STUDY USING INTRAVASCULAR ULTRASOUND [J].
FITZGERALD, PJ ;
PORTS, TA ;
YOCK, PG .
CIRCULATION, 1992, 86 (01) :64-70
[9]   ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY [J].
GUSSENHOVEN, EJ ;
ESSED, CE ;
LANCEE, CT ;
MASTIK, F ;
FRIETMAN, P ;
VANEGMOND, FC ;
REIBER, J ;
BOSCH, H ;
VANURK, H ;
ROELANDT, J ;
BOM, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) :947-952
[10]   INVIVO VALIDATION OF COMPENSATORY ENLARGEMENT OF ATHEROSCLEROTIC CORONARY-ARTERIES [J].
HERMILLER, JB ;
TENAGLIA, AN ;
KISSLO, KB ;
PHILLIPS, HR ;
BASHORE, TM ;
STACK, RS ;
DAVIDSON, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (08) :665-668