High-precision Cu and Zn isotope analysis by plasma source mass spectrometry - Part 2. Correcting for mass discrimination effects

被引:135
作者
Mason, TFD [1 ]
Weiss, DJ
Horstwood, M
Parrish, RR
Russell, SS
Mullane, E
Coles, BJ
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Earth Sci & Engn, London SW7 2BP, England
[2] Nat Hist Museum, Dept Mineral, London SW7 5BD, England
[3] NERC, Isotope Geosci Lab, Keyworth NG12 5GG, Notts, England
[4] Univ Leicester, Dept Geol, Leicester LE1 7RH, Leics, England
关键词
D O I
10.1039/b306953b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two approaches to correct for mass discrimination effects associated with Cu and Zn isotopic measurements on two different MC-ICP-MS instruments (a Micromass IsoProbe and a VG Axiom) have been compared and assessed in detail: (1) sample-standard bracketing (SSB), and (2) the 'empirical external normalisation' (EEN) whereby a second element is used to simultaneously correct for mass discrimination. This has provided new insights into the mass discrimination behaviours of Cu and Zn under varying instrumental set-ups, and has allowed improvements to be made to the existing correction procedures. With the SSB approach, mass bias stability is a prerequisite, and matrix components must be removed from the analyte to avoid matrix-related mass discrimination effects. By comparison, the EEN approach requires a degree of mass bias instability, and automatically corrects for matrix-related mass discrimination effects. The EEN correction may therefore appear more robust. However, while the EEN correction yields high-precision Cu-65/Cu-63 and Zn-66/Zn-64 data, an as yet unidentified source of systematic drift in the Zn-67 and Zn-68 signals through time hinders analyses of ratios incorporating these isotopes. Using the EEN correction where analyte and spike ratios were measured sequentially within a peak-switching protocol led to a three-fold deterioration in precision relative to static measurements. This is consistent with mass bias drift on the scale of a single five-second-measurement integration. For relative Cu-65/Cu-63 and Zn-66/Zn-64 ratio measurements, the SSB and EEN corrections give long-term reproducibilities of less then +/-0.07parts per thousand. (2SD) for pure Cu and Zn reagents. This is sufficient for resolving mass-dependent isotopic variability in natural and anthropogenic materials.
引用
收藏
页码:218 / 226
页数:9
相关论文
共 43 条
[1]   Precise determination of mass-dependent variations in the isotopic composition of molybdenum using MC-ICPMS [J].
Anbar, AD ;
Knab, KA ;
Barling, J .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1425-1431
[2]   Application of Fe isotopes to tracing the geochemical and biological cycling of Fe [J].
Beard, BL ;
Johnson, CM ;
Skulan, JL ;
Nealson, KH ;
Cox, L ;
Sun, H .
CHEMICAL GEOLOGY, 2003, 195 (1-4) :87-117
[3]   High precision measurement of iron isotopes by plasma source mass spectrometry [J].
Belshaw, NS ;
Zhu, XK ;
Guo, Y ;
O'Nions, RK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 :191-195
[4]  
CARLSON RW, 2002, PLASMA SOURCE MASS S
[5]   Precise determination of the isotopic composition of Sn using MC-ICP-MS [J].
Clayton, R ;
Andersson, P ;
Gale, NH ;
Gillis, C ;
Whitehouse, MJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) :1248-1256
[6]   ISOTOPE RATIO MEASUREMENTS ON SOLUTION SAMPLES USING A PLASMA ION-SOURCE [J].
DATE, AR ;
GRAY, AL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 48 (FEB) :357-360
[7]   High precision lead isotope ratio measurements by multicollector-ICP-MS in variable matrices [J].
Ehrlich, S ;
Karpas, Z ;
Ben-Dor, L ;
Halicz, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :975-977
[8]  
Freedman PA, 2002, GEOCHIM COSMOCHIM AC, V66, pA245
[9]   Natural variations detected in the isotopic composition of copper: possible applications to archaeology and geochemistry [J].
Gale, NH ;
Woodhead, AP ;
Stos-Gale, ZA ;
Walder, A ;
Bowen, I .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 184 (01) :1-9
[10]   High-precision measurement of magnesium isotopes by multiple-collector inductively coupled plasma mass spectrometry [J].
Galy, A ;
Belshaw, NS ;
Halicz, L ;
O'Nions, RK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) :89-98