High precision lead isotope ratio measurements by multicollector-ICP-MS in variable matrices

被引:28
作者
Ehrlich, S
Karpas, Z
Ben-Dor, L
Halicz, L
机构
[1] Geol Survey Israel, IL-95501 Jerusalem, Israel
[2] Nucl Res Ctr Negev, IL-84190 Beer Sheva, Israel
[3] Hebrew Univ Jerusalem, Dept Inorgan & Analyt Chem, IL-91904 Jerusalem, Israel
关键词
D O I
10.1039/b102454j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is well known that the use of thallium as an internal standard for high precision and high accuracy measurement of lead isotopic ratios can correct for mass discrimination and instrumental drift. The present work demonstrates that matrix effects can also be accounted for when a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) is used. The precision (2 sigma) obtained for the Pb-207/Pb-206 and Pb-208/Pb-206 ratios was 30 and 40 ppm, respectively, even in samples with total dissolved solid (TDS) levels of up to 700 mg L-1.
引用
收藏
页码:975 / 977
页数:3
相关论文
共 19 条
[1]   A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes [J].
Belshaw, NS ;
Freedman, PA ;
O'Nions, RK ;
Frank, M ;
Guo, Y .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :51-58
[2]   ABSOLUTE ISOTOPIC ABUNDANCE RATIOS OF COMMON EQUAL-ATOM AND RADIOGENIC LEAD ISOTOPIC STANDARDS [J].
CATANZARO, EJ ;
MURPHY, TJ ;
SHIELDS, WR ;
GARNER, EL .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION A-PHYSICS AND CHEMISTRY, 1968, A 72 (03) :261-+
[3]   Climate and ocean dynamics and the lead isotopic records in Pacific ferromanganese crusts [J].
Christensen, JN ;
Halliday, AN ;
Godfrey, LV ;
Hein, JR ;
Rea, DK .
SCIENCE, 1997, 277 (5328) :913-918
[4]  
DAWSON PH, 1976, QUADRUPOLE MASS SPEC, P143
[5]  
Galer S. J. G., 1998, MINERAL MAG A, V62, P491, DOI DOI 10.1180/MINMAG.1998.62A.1.260
[6]   Applications of multiple collector-ICPMS to cosmochemistry, geochemistry, and paleoceanography [J].
Halliday, AN ;
Lee, DC ;
Christensen, JN ;
Rehkamper, M ;
Yi, W ;
Luo, XZ ;
Hall, CM ;
Ballentine, CJ ;
Pettke, T ;
Stirling, C .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1998, 62 (06) :919-940
[7]  
Heumann KG, 1998, J ANAL ATOM SPECTROM, V13, P1001
[8]   Lead isotopic analyses of NIST standard reference materials using multiple collector inductively coupled plasma mass spectrometry coupled with a modified external correction method for mass discrimination effect [J].
Hirata, T .
ANALYST, 1996, 121 (10) :1407-1411
[9]   DETERMINATION OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) [J].
LONGERICH, HP ;
FRYER, BJ ;
STRONG, DF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :39-48
[10]   RECENT DATA ON LEAD ISOTOPE MEASUREMENTS [J].
PLATZNER, I .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 77 (2-3) :155-163