Amperometric TNT biosensor based on the oriented immobilization of a nitroreductase maltose binding protein fusion

被引:84
作者
Naal, Z
Park, JH
Bernhard, S
Shapleigh, JP
Batt, CA
Abruña, HD
机构
[1] Cornell Univ, Dept Chem & Chem Engn, Baker Lab, Ithaca, NY 14853 USA
[2] Cornell Univ, Dept Microbiol, Ithaca, NY 14853 USA
[3] Cornell Univ, Dept Food Sci, Ithaca, NY 14853 USA
关键词
D O I
10.1021/ac010596o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation and characterization of an amperometric 2,4,6-trinitrotoluene (TNT) biosensor based on the surface immobilization of a maltose binding protein (MBP) nitroreductase (NR) fusion (MBP-NR) onto an electrode modified with an electropolymerized film of N-(3-pyrrol-1-ylpropyl)-4,4'-bipyridine (PPB) are described. The MBP domain of MBP-NR exhibits a high and specific affinity toward electropolymerized films of PPB with the immobilized enzyme retaining virtually all of its enzymatic activity. Under similar conditions, the wild-type NR enzyme (i.e., without the MBP domain) loses most of its enzymatic activity. The kinetics of the catalytic reaction between the biosensor and TNT and 2,4-dinitrotoluene (DNT) were characterized using rotated disk electrode and cyclic voltammetry techniques, and values of 1.4 x 10(4) and 7.1 x 10(4) M-1 s(-1) were obtained for TNT and DNT, respectively. The apparent Michaelis - Menten constants (K-M) for MBP-NR in solution and on the surface, using TNT as substrate, were determined to be 27 and 95 muM, respectively. The corresponding value for "wild-type" NR in solution containing TNT was 78 muM, which is very close to the value obtained for MBP-NR on the surface. The limits of detection for both TNT and DNT were estimated to be 2 muM, and the sensitivities were determined to be 205 and 222 nA/muM, respectively.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 42 条
[31]   REDUCTION OF NITRATE AND NITRITE IN WATER BY IMMOBILIZED ENZYMES [J].
MELLOR, RB ;
RONNENBERG, J ;
CAMPBELL, WH ;
DIEKMANN, S .
NATURE, 1992, 355 (6362) :717-719
[32]   Genetic engineering of a single-chain antibody fragment for surface immobilization in an optical biosensor [J].
Piervincenzi, RT ;
Reichert, WM ;
Hellinga, HW .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) :305-312
[33]   A membrane-based displacement flow immunoassay [J].
Rabbany, SY ;
Marganski, WA ;
Kusterbeck, AW ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (09) :939-944
[34]   Utility of wiring nitrate reductase by alkylpyrroleviologen-based redox polymers for electrochemical biosensor and bioreactor applications [J].
Ramsay, G ;
Wolpert, SM .
ANALYTICAL CHEMISTRY, 1999, 71 (02) :504-506
[35]   IMPROVING ENZYME-ELECTRODE CONTACTS BY REDOX MODIFICATION OF COFACTORS [J].
RIKLIN, A ;
KATZ, E ;
WILLNER, I ;
STOCKER, A ;
BUCKMANN, AF .
NATURE, 1995, 376 (6542) :672-675
[36]  
Sambrook J., 2002, MOL CLONING LAB MANU
[37]   A glucose oxidase electrode based on electropolymerized conducting polymer with polyanion-enzyme conjugated dopant [J].
Sung, WJ ;
Bae, YH .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2177-2181
[38]  
TAKADA K, UNPUB
[39]  
TURNER APF, 1988, METHOD ENZYMOL, V137, P90
[40]   PROTEIN-MODIFIED ELECTRODES - THE GLUCOSE-OXIDASE POLYPYRROLE SYSTEM [J].
UMANA, M ;
WALLER, J .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :2979-2983