High-performance liquid chromatography of methotrexate for environmental monitoring of surface contamination in hospital departments and assessment of occupational exposure

被引:31
作者
Floridia, L
Pietropaolo, AM
Tavazzani, M
Rubino, FM
Colombi, A
机构
[1] ICP, CEMOC, Lab Ind Toxicol & Occupat Allergol, I-20141 Milan, Italy
[2] Univ Milan, Clin L Devoto, Dipartimento Med Lavoro, I-20122 Milan, Italy
来源
JOURNAL OF CHROMATOGRAPHY B | 1999年 / 726卷 / 1-2期
关键词
methotrexate;
D O I
10.1016/S0378-4347(98)00561-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the frame of applicative research in occupational hygiene of hospital workplaces, we investigate hospital indoor contamination as a consequence of the use of antineoplastic drugs (ANDs), with the purpose of assessing exposure of medical and nursing personnel to potentially harmful doses of ANDs, and ultimately of yielding advice on safe operating procedures for manipulation of ANDs in hospitals and in house-care of cancer patients. Among the large number of currently employed ANDs, methotrexate (MTX) has been selected as a tracer of surface contamination, on the basis of its wide use in therapy, its ease of measurement and of its chemical properties relevant to persistence and transport in the indoor environment, MTX is a polyelectrolyte, with a high water, but lower organic solvent solubility, a negligible vapour pressure and a high chemical robustness to environmental stress, thus allowing to measure surface-to-surface carryover (e.g. from spillage or glove fingerprint) and indoor contamination due to aerosol transport (e.g. from syringe manipulation procedures). Monitoring of MTX in environmental samples such as swab washings of surfaces and objects requires an analytical method with characteristics of sensitivity, reproducibility, precision, analytical speed, ease of automation and robustness. We have therefore developed an analytical procedure which employs simple short-column RP-HPLC with UV detection, automated sample injection and a close analogue internal standard for improved precision and solid-phase extraction (SPE) for sample concentration. Our method has proven suitable for detecting traces of MTX on a wide variety of surfaces and objects, with a limit of quantification in the range of 50 mu g/dm(3) for direct injection of unconcentrated washings, corresponding to the possible detection of surface contamination as low as 1 mu g/m(3) and a limit of detection in the range of 10 ng/m(2) for samples as large as 100 dm(3) concentrated by SPE. We present preliminary results from a recent hospital case-study, assessing the contamination level of furniture and equipment in drug preparation areas. Spillage fractions as high as 5% of the employed mass (70-260 mg/day) are measured on the polythene-backed paper disposable hood cover sheet; traces of MTX in the microgram range can also be measured on floor surfaces, furniture and handles, even at a distance from the preparation hoods. (C) 1999 Published by Elsevier Science BN. All rights reserved.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 22 条
[1]   Determination of methotrexate in serum by high-performance liquid chromatography [J].
Aboleneen, H ;
Simpson, J ;
Backes, D .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (02) :317-322
[2]  
ANDERSON RW, 1982, AM J HOSP PHARM, V39, P17
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR SERUM METHOTREXATE LEVELS IN CHILDREN WITH SEVERE STEROID-DEPENDENT ASTHMA [J].
ASSADULLAHI, TP ;
DAGLI, E ;
WARNER, JO .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 565 (1-2) :349-356
[4]   RAPID AND SIMPLE ASSAY FOR THE MEASUREMENT OF METHOTREXATE IN SERUM, URINE AND RED-BLOOD-CELLS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BRIMMELL, PA ;
SAMS, DJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 413 :320-325
[5]   SENSITIVE AND RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE SIMULTANEOUS DETERMINATION OF METHOTREXATE AND ITS METABOLITES IN PLASMA, SALIVA AND URINE [J].
CHEN, ML ;
CHIOU, WL .
JOURNAL OF CHROMATOGRAPHY, 1981, 226 (01) :125-134
[6]   DETERMINATION OF METHOTREXATE AND 7-HYDROXYMETHOTREXATE BY LIQUID-CHROMATOGRAPHY FOR ROUTINE MONITORING OF PLASMA-LEVELS [J].
COCIGLIO, M ;
HILLAIREBUYS, D ;
ALRIC, C .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 674 (01) :101-110
[7]  
DEW NA, 1982, AM J HOSP PHARM, V40, P597
[8]  
FALCK K, 1979, LANCET, V1, P1250
[9]   Determination of methotrexate and its main metabolite 7-hydroxymethotrexate in human urine by high-performance liquid chromatography with normal solid-phase extraction [J].
Hirai, T ;
Matsumoto, S ;
Kishi, I .
JOURNAL OF CHROMATOGRAPHY B, 1997, 690 (1-2) :267-273
[10]   CARCINOGENICITY OF SOME ANTICANCER DRUGS - A SURVEY [J].
LIEN, EJ ;
OU, XC .
JOURNAL OF CLINICAL AND HOSPITAL PHARMACY, 1985, 10 (03) :223-242